CivilAxisCivilAxis
☕ Support🌐 Community

CF CHS 508×6 - Section Properties

The CF CHS 508×6 is a circular hollow section with a mass of 74.3 kg/m, an overall depth of 508 mm and width of 508 mm and a wall thickness of 6 mm. It has a cross-sectional area of 94.6 cm², a second moment of area Iᵧ of 29800 cm⁴, a plastic modulus Wₚₗ,ᵧ of 1510 cm³, tabulated by CivilAxis from BS EN 10219-2:2006 (SCI P363 Blue Book).

Mass
74.3 kg/m
Diameter
508 mm
Wall thickness
6 mm
Area
94.6 cm²
Ask about capacity, buckling or detailing for CF CHS 508×6.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
CHS Cold-formed section profile showing the dimension symbols used for CF CHS 508×6

Dimension symbols for CHS Cold-formed sections. Not to scale.

CF CHS 508×6 section properties to BS EN 10219-2:2006.

Geometry

Depth of sectionh508
Width of sectionb508
Wall thicknesst6

Mass and area

Mass per metremass74.3
Cross-sectional areaA94.6

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy29800
Elastic section modulus about y-axisWel,y1170
Plastic section modulus about y-axisWpl,y1510
Radius of gyration about y-axisiy17.7

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz29800
Elastic section modulus about z-axisWel,z1170
Plastic section modulus about z-axisWpl,z1510
Radius of gyration about z-axisiz17.7

Torsion and warping

Torsion constant (St Venant)It59600
Section modulus for torsionWt2350

Surface area

Surface area per metreSA/m21.6

Common questions about CF CHS 508×6

CF CHS 508×6 has a mass of 74.3 kg/m, tabulated to BS EN 10219-2:2006. A 12 m length therefore weighs about 892 kg, which is the figure to use for a steel take-off or when checking a lift.

CF CHS 508×6 has a depth of 508 mm, a width of 508 mm, a wall thickness of 6 mm, with a cross-sectional area of 94.6 cm². These are the nominal dimensions from BS EN 10219-2:2006; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 1,510 cm³, and the elastic modulus Wel,y is 1,170 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 536 kNm before any stability check.

The second moment of area about the major axis, Iy, is 29,800 cm⁴, and about the minor axis Iz is 29,800 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 17.7 cm about the major axis and iz is 17.7 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 17.7 cm a 1.8 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 59,600 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related CHS Cold-formed sizes

CF CHS 457×10CF CHS 457×12CF CHS 457×12.5CF CHS 457×16CF CHS 508×6.3CF CHS 508×8CF CHS 508×10CF CHS 508×12

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All CHS Cold-formed sizes
Circular Hollow Sections - Cold-formed (BS EN 10219)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…