CivilAxisCivilAxis
☕ Support🌐 Community

CHS 21.3×2.9 - Section Properties

The CHS 21.3×2.9 is a circular hollow section with a mass of 1.32 kg/m, an overall depth of 21.3 mm and width of 21.3 mm and a wall thickness of 2.9 mm. It has a cross-sectional area of 1.68 cm², a second moment of area Iᵧ of 0.727 cm⁴, a plastic modulus Wₚₗ,ᵧ of 0.99 cm³, tabulated by CivilAxis from BS EN 10210-2:2006 (SCI P363 Blue Book).

Mass
1.32 kg/m
Diameter
21.3 mm
Wall thickness
2.9 mm
Area
1.68 cm²
Ask about capacity, buckling or detailing for CHS 21.3×2.9.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
CHS Hot-finished section profile showing the dimension symbols used for CHS 21.3×2.9

Dimension symbols for CHS Hot-finished sections. Not to scale.

CHS 21.3×2.9 section properties to BS EN 10210-2:2006.

Geometry

Depth of sectionh21.3
Width of sectionb21.3
Wall thicknesst2.9

Mass and area

Mass per metremass1.32
Cross-sectional areaA1.68

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy0.727
Elastic section modulus about y-axisWel,y0.683
Plastic section modulus about y-axisWpl,y0.99
Radius of gyration about y-axisiy0.659

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz0.727
Elastic section modulus about z-axisWel,z0.683
Plastic section modulus about z-axisWpl,z0.99
Radius of gyration about z-axisiz0.659

Torsion and warping

Torsion constant (St Venant)It1.45
Section modulus for torsionWt1.37

Surface area

Surface area per metreSA/m0.067
Surface area per tonneSA/t50.9m²/t

Is CHS 21.3×2.9 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 58% utilised, deflection governs
Bending20%
0.1 / 0.4 kNm
Shear3%
0.6 / 17.2 kN
Deflection58%
0.8 / 1.4 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about CHS 21.3×2.9

CHS 21.3×2.9 has a mass of 1.32 kg/m, tabulated to BS EN 10210-2:2006. A 12 m length therefore weighs about 16 kg, which is the figure to use for a steel take-off or when checking a lift.

CHS 21.3×2.9 has a depth of 21.3 mm, a width of 21.3 mm, a wall thickness of 2.9 mm, with a cross-sectional area of 1.68 cm². These are the nominal dimensions from BS EN 10210-2:2006; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 0.99 cm³, and the elastic modulus Wel,y is 0.683 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 0 kNm before any stability check.

The second moment of area about the major axis, Iy, is 0.727 cm⁴, and about the minor axis Iz is 0.727 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 0.659 cm about the major axis and iz is 0.659 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 0.659 cm a 0.1 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 1.45 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related CHS Hot-finished sizes

CHS 21.3×2.6CHS 21.3×3.2CHS 26.9×2.6CHS 26.9×2.9CHS 26.9×3.2CHS 26.9×3.6CHS 33.7×2.6CHS 33.7×2.9

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All CHS Hot-finished sizes
Circular Hollow Sections - Hot-finished (BS EN 10210)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…