CHS 244.5×14.2 - Section Properties

The CHS 244.5×14.2 is a circular hollow section with a mass of 80.6 kg/m, an overall depth of 244.5 mm and width of 244.5 mm and a wall thickness of 14.2 mm. It has a cross-sectional area of 103 cm², a second moment of area Iᵧ of 6840 cm⁴, a plastic modulus Wₚₗ,ᵧ of 754 cm³, tabulated by CivilAxis from BS EN 10210-2:2006 (SCI P363 Blue Book).

Mass
80.6 kg/m
Diameter
244.5 mm
Wall thickness
14.2 mm
Area
103 cm²
Ask about capacity, buckling or detailing for CHS 244.5×14.2.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
CHS Hot-finished section profile showing the dimension symbols used for CHS 244.5×14.2

Dimension symbols for CHS Hot-finished sections. Not to scale.

CHS 244.5×14.2 section properties to BS EN 10210-2:2006.

Geometry

Depth of sectionh244.5
Width of sectionb244.5
Wall thicknesst14.2

Mass and area

Mass per metremass80.6
Cross-sectional areaA103

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy6840
Elastic section modulus about y-axisWel,y559
Plastic section modulus about y-axisWpl,y754
Radius of gyration about y-axisiy8.16

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz6840
Elastic section modulus about z-axisWel,z559
Plastic section modulus about z-axisWpl,z754
Radius of gyration about z-axisiz8.16

Torsion and warping

Torsion constant (St Venant)It13700
Section modulus for torsionWt1120

Surface area

Surface area per metreSA/m0.768
Surface area per tonneSA/t9.52m²/t

Is CHS 244.5×14.2 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending26%
70.3 / 267.7 kNm
Shear5%
56.3 / 1055.5 kN
Deflection61%
8.5 / 13.9 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about CHS 244.5×14.2

CHS 244.5×14.2 has a mass of 80.6 kg/m, tabulated to BS EN 10210-2:2006. A 12 m length therefore weighs about 967 kg, which is the figure to use for a steel take-off or when checking a lift.

CHS 244.5×14.2 has a depth of 244.5 mm, a width of 244.5 mm, a wall thickness of 14.2 mm, with a cross-sectional area of 103 cm². These are the nominal dimensions from BS EN 10210-2:2006; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 754 cm³, and the elastic modulus Wel,y is 559 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 268 kNm before any stability check.

The second moment of area about the major axis, Iy, is 6,840 cm⁴, and about the minor axis Iz is 6,840 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 8.16 cm about the major axis and iz is 8.16 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 8.16 cm a 0.8 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 13,700 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related CHS Hot-finished sizes

CHS 244.5×6.3CHS 244.5×8CHS 244.5×10CHS 244.5×12.5CHS 244.5×16CHS 273×5CHS 273×5.6CHS 273×6.3

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All CHS Hot-finished sizes
Circular Hollow Sections - Hot-finished (BS EN 10210)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…