CivilAxisCivilAxis
☕ Support🌐 Community

CHS 60.3×8 - Section Properties

The CHS 60.3×8 is a circular hollow section with a mass of 10.3 kg/m, an overall depth of 60.3 mm and width of 60.3 mm and a wall thickness of 8 mm. It has a cross-sectional area of 13.1 cm², a second moment of area Iᵧ of 46 cm⁴, a plastic modulus Wₚₗ,ᵧ of 22.1 cm³, tabulated by CivilAxis from BS EN 10210-2:2006 (SCI P363 Blue Book).

Mass
10.3 kg/m
Diameter
60.3 mm
Wall thickness
8 mm
Area
13.1 cm²
Ask about capacity, buckling or detailing for CHS 60.3×8.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
CHS Hot-finished section profile showing the dimension symbols used for CHS 60.3×8

Dimension symbols for CHS Hot-finished sections. Not to scale.

CHS 60.3×8 section properties to BS EN 10210-2:2006.

Geometry

Depth of sectionh60.3
Width of sectionb60.3
Wall thicknesst8

Mass and area

Mass per metremass10.3
Cross-sectional areaA13.1

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy46
Elastic section modulus about y-axisWel,y15.3
Plastic section modulus about y-axisWpl,y22.1
Radius of gyration about y-axisiy1.87

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz46
Elastic section modulus about z-axisWel,z15.3
Plastic section modulus about z-axisWpl,z22.1
Radius of gyration about z-axisiz1.87

Torsion and warping

Torsion constant (St Venant)It92
Section modulus for torsionWt30.5

Surface area

Surface area per metreSA/m0.189
Surface area per tonneSA/t18.3m²/t

Is CHS 60.3×8 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 58% utilised, deflection governs
Bending29%
2.3 / 7.8 kNm
Shear7%
9.0 / 134.2 kN
Deflection58%
1.6 / 2.8 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about CHS 60.3×8

CHS 60.3×8 has a mass of 10.3 kg/m, tabulated to BS EN 10210-2:2006. A 12 m length therefore weighs about 124 kg, which is the figure to use for a steel take-off or when checking a lift.

CHS 60.3×8 has a depth of 60.3 mm, a width of 60.3 mm, a wall thickness of 8 mm, with a cross-sectional area of 13.1 cm². These are the nominal dimensions from BS EN 10210-2:2006; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 22.1 cm³, and the elastic modulus Wel,y is 15.3 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 8 kNm before any stability check.

The second moment of area about the major axis, Iy, is 46 cm⁴, and about the minor axis Iz is 46 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 1.87 cm about the major axis and iz is 1.87 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 1.87 cm a 0.2 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 92 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related CHS Hot-finished sizes

CHS 60.3×4.5CHS 60.3×5CHS 60.3×5.6CHS 60.3×6.3CHS 76.1×2.9CHS 76.1×3.2CHS 76.1×3.6CHS 76.1×4

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All CHS Hot-finished sizes
Circular Hollow Sections - Hot-finished (BS EN 10210)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.