RHS 100×75×4 - Section Properties
The RHS 100×75×4 is a steel section with a mass of 10.2 kg/m, an overall depth of 100 mm and width of 75 mm and a wall thickness of 4 mm. It has a cross-sectional area of 12.9 cm², a second moment of area Iᵧ of 180 cm⁴, a plastic modulus Wₚₗ,ᵧ of 43.7 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.
Ask about capacity, buckling or detailing for RHS 100×75×4.
or pick a unit on any row

Dimension symbols for RHS Cold-formed sections. Not to scale.
Is RHS 100×75×4 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 60% utilised, deflection governs
Bending29%
4.5 / 15.5 kNmShear6%
9.0 / 151.1 kNDeflection60%
3.3 / 5.6 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about RHS 100×75×4
Related RHS Cold-formed sizes
Compare with other sections
Side-by-side properties against the closest equivalent in each catalogue.
Learn more
Rate thisNo ratings yet
Sign in to join the discussion.