RHS 100×75×5 - Section Properties
The RHS 100×75×5 is a steel section with a mass of 12.8 kg/m, an overall depth of 100 mm and width of 75 mm and a wall thickness of 5 mm. It has a cross-sectional area of 15.9 cm², a second moment of area Iᵧ of 215 cm⁴, a plastic modulus Wₚₗ,ᵧ of 52.7 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.
Ask about capacity, buckling or detailing for RHS 100×75×5.
or pick a unit on any row

Dimension symbols for RHS Cold-formed sections. Not to scale.
Is RHS 100×75×5 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 58% utilised, deflection governs
Bending28%
5.3 / 18.7 kNmShear6%
10.5 / 186.2 kNDeflection58%
3.2 / 5.6 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about RHS 100×75×5
Related RHS Cold-formed sizes
Learn more
Rate thisNo ratings yet
Sign in to join the discussion.