CivilAxisCivilAxis
☕ Support🌐 Community

RHS 150×75×5 - Section Properties

The RHS 150×75×5 is a steel section with a mass of 16.7 kg/m, an overall depth of 150 mm and width of 75 mm and a wall thickness of 5 mm. It has a cross-sectional area of 20.9 cm², a second moment of area Iᵧ of 588 cm⁴, a plastic modulus Wₚₗ,ᵧ of 98.6 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.

Mass
16.7 kg/m
Depth
150 mm
Width
75 mm
Wall thickness
5 mm
Area
20.9 cm²
Ask about capacity, buckling or detailing for RHS 150×75×5.
🔍 Open the full Steel Catalogue
or pick a unit on any row
RHS Cold-formed section profile showing the dimension symbols used for RHS 150×75×5

Dimension symbols for RHS Cold-formed sections. Not to scale.

RHS 150×75×5 section properties to EN 10219 · Continental Steel.

Geometry

Depth of sectionh150
Width of sectionb75
Wall thicknesst5

Mass and area

Mass per metremass16.7
Cross-sectional areaA20.9

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy588
Elastic section modulus about y-axisWel,y78.4
Plastic section modulus about y-axisWpl,y98.6
Radius of gyration about y-axisiy5.31

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz198
Elastic section modulus about z-axisWel,z52.9
Plastic section modulus about z-axisWpl,z60.7
Radius of gyration about z-axisiz3.08

Torsion and warping

Torsion constant (St Venant)It491
Section modulus for torsionWt91.9

Surface area

Surface area per metreSA/m0.433

Is RHS 150×75×5 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending29%
10.1 / 35.0 kNm
Shear5%
13.5 / 285.6 kN
Deflection61%
5.1 / 8.3 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about RHS 150×75×5

RHS 150×75×5 has a mass of 16.7 kg/m, tabulated to EN 10219. A 12 m length therefore weighs about 200 kg, which is the figure to use for a steel take-off or when checking a lift.

RHS 150×75×5 has a depth of 150 mm, a width of 75 mm, a wall thickness of 5 mm, with a cross-sectional area of 20.9 cm². These are the nominal dimensions from EN 10219; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 98.6 cm³, and the elastic modulus Wel,y is 78.4 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 35 kNm before any stability check.

The second moment of area about the major axis, Iy, is 588 cm⁴, and about the minor axis Iz is 198 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 5.31 cm about the major axis and iz is 3.08 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 3.08 cm a 0.3 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 491 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related RHS Cold-formed sizes

RHS 150×75×4RHS 150×75×4.5RHS 150×75×4.6RHS 150×75×4.8RHS 150×75×6RHS 150×75×6.4RHS 150×75×9RHS 150×100×3

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs RHS 150×100×4

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All RHS Cold-formed sizes
Rectangular Hollow Sections - Cold-formed
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…