RHS 150×75×9 - Section Properties
The RHS 150×75×9 is a steel section with a mass of 27.6 kg/m, an overall depth of 150 mm and width of 75 mm and a wall thickness of 9 mm. It has a cross-sectional area of 34.5 cm², a second moment of area Iᵧ of 865 cm⁴, a plastic modulus Wₚₗ,ᵧ of 153 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.
Ask about capacity, buckling or detailing for RHS 150×75×9.
or pick a unit on any row

Dimension symbols for RHS Cold-formed sections. Not to scale.
Is RHS 150×75×9 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 59% utilised, deflection governs
Bending26%
14.3 / 54.3 kNmShear4%
19.1 / 471.4 kNDeflection59%
4.9 / 8.3 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about RHS 150×75×9
Related RHS Cold-formed sizes
Learn more
Rate thisNo ratings yet
Sign in to join the discussion.