CivilAxisCivilAxis
☕ Support🌐 Community

RHS 300×200×10 - Section Properties

The RHS 300×200×10 is a steel section with a mass of 72.7 kg/m, an overall depth of 300 mm and width of 200 mm and a wall thickness of 10 mm. It has a cross-sectional area of 92.6 cm², a second moment of area Iᵧ of 11310 cm⁴, a plastic modulus Wₚₗ,ᵧ of 921 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.

Mass
72.7 kg/m
Depth
300 mm
Width
200 mm
Wall thickness
10 mm
Area
92.6 cm²
Ask about capacity, buckling or detailing for RHS 300×200×10.
🔍 Open the full Steel Catalogue
or pick a unit on any row
RHS Cold-formed section profile showing the dimension symbols used for RHS 300×200×10

Dimension symbols for RHS Cold-formed sections. Not to scale.

RHS 300×200×10 section properties to EN 10219 · Continental Steel.

Geometry

Depth of sectionh300
Width of sectionb200
Wall thicknesst10

Mass and area

Mass per metremass72.7
Cross-sectional areaA92.6

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy11310
Elastic section modulus about y-axisWel,y754
Plastic section modulus about y-axisWpl,y921
Radius of gyration about y-axisiy11.1

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz6058
Elastic section modulus about z-axisWel,z606
Plastic section modulus about z-axisWpl,z698
Radius of gyration about z-axisiz8.09

Torsion and warping

Torsion constant (St Venant)It12990
Section modulus for torsionWt1012

Surface area

Surface area per metreSA/m0.957

Is RHS 300×200×10 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending29%
94.5 / 327.0 kNm
Shear6%
63.0 / 1138.8 kN
Deflection60%
9.9 / 16.7 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about RHS 300×200×10

RHS 300×200×10 has a mass of 72.7 kg/m, tabulated to EN 10219. A 12 m length therefore weighs about 872 kg, which is the figure to use for a steel take-off or when checking a lift.

RHS 300×200×10 has a depth of 300 mm, a width of 200 mm, a wall thickness of 10 mm, with a cross-sectional area of 92.6 cm². These are the nominal dimensions from EN 10219; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 921 cm³, and the elastic modulus Wel,y is 754 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 327 kNm before any stability check.

The second moment of area about the major axis, Iy, is 11,310 cm⁴, and about the minor axis Iz is 6,058 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 11.1 cm about the major axis and iz is 8.09 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 8.09 cm a 0.8 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 12,990 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related RHS Cold-formed sizes

RHS 300×200×6RHS 300×200×6.3RHS 300×200×8RHS 300×200×9RHS 300×200×12RHS 300×200×12.5RHS 400×200×6RHS 400×200×8

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs RHS 300×100×14.2vs RHS 300×250×8

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All RHS Cold-formed sizes
Rectangular Hollow Sections - Cold-formed
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.