CivilAxisCivilAxis
☕ Support🌐 Community

RHS 300×200×12 - Section Properties

The RHS 300×200×12 is a steel section with a mass of 84.8 kg/m, an overall depth of 300 mm and width of 200 mm and a wall thickness of 12 mm. It has a cross-sectional area of 108 cm², a second moment of area Iᵧ of 12790 cm⁴, a plastic modulus Wₚₗ,ᵧ of 1056 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.

Mass
84.8 kg/m
Depth
300 mm
Width
200 mm
Wall thickness
12 mm
Area
108 cm²
Ask about capacity, buckling or detailing for RHS 300×200×12.
🔍 Open the full Steel Catalogue
or pick a unit on any row
RHS Cold-formed section profile showing the dimension symbols used for RHS 300×200×12

Dimension symbols for RHS Cold-formed sections. Not to scale.

RHS 300×200×12 section properties to EN 10219 · Continental Steel.

Geometry

Depth of sectionh300
Width of sectionb200
Wall thicknesst12

Mass and area

Mass per metremass84.8
Cross-sectional areaA108

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy12790
Elastic section modulus about y-axisWel,y853
Plastic section modulus about y-axisWpl,y1056
Radius of gyration about y-axisiy10.9

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz6854
Elastic section modulus about z-axisWel,z685
Plastic section modulus about z-axisWpl,z801
Radius of gyration about z-axisiz7.96

Torsion and warping

Torsion constant (St Venant)It15240
Section modulus for torsionWt1167

Surface area

Surface area per metreSA/m0.938

Is RHS 300×200×12 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending29%
108.0 / 374.9 kNm
Shear5%
72.0 / 1328.1 kN
Deflection60%
10.1 / 16.7 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about RHS 300×200×12

RHS 300×200×12 has a mass of 84.8 kg/m, tabulated to EN 10219. A 12 m length therefore weighs about 1018 kg, which is the figure to use for a steel take-off or when checking a lift.

RHS 300×200×12 has a depth of 300 mm, a width of 200 mm, a wall thickness of 12 mm, with a cross-sectional area of 108 cm². These are the nominal dimensions from EN 10219; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 1,056 cm³, and the elastic modulus Wel,y is 853 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 375 kNm before any stability check.

The second moment of area about the major axis, Iy, is 12,790 cm⁴, and about the minor axis Iz is 6,854 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 10.9 cm about the major axis and iz is 7.96 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 7.96 cm a 0.8 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 15,240 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related RHS Cold-formed sizes

RHS 300×200×6.3RHS 300×200×8RHS 300×200×9RHS 300×200×10RHS 300×200×12.5RHS 400×200×6RHS 400×200×8RHS 400×200×9

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All RHS Cold-formed sizes
Rectangular Hollow Sections - Cold-formed
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…