RHS 75×50×4 - Section Properties
The RHS 75×50×4 is a steel section with a mass of 7.08 kg/m, an overall depth of 75 mm and width of 50 mm and a wall thickness of 4 mm. It has a cross-sectional area of 8.95 cm², a second moment of area Iᵧ of 65 cm⁴, a plastic modulus Wₚₗ,ᵧ of 21.7 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.
Ask about capacity, buckling or detailing for RHS 75×50×4.
or pick a unit on any row

Dimension symbols for RHS Cold-formed sections. Not to scale.
Is RHS 75×50×4 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 58% utilised, deflection governs
Bending27%
2.1 / 7.7 kNmShear5%
5.6 / 110.1 kNDeflection58%
2.4 / 4.2 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about RHS 75×50×4
Related RHS Cold-formed sizes
Learn more
Rate thisNo ratings yet
Sign in to join the discussion.