SHS 250×250×12.5 - Section Properties

The SHS 250×250×12.5 is a steel section with a mass of 88 kg/m, an overall depth of 250 mm and width of 250 mm and a wall thickness of 12.5 mm. It has a cross-sectional area of 112 cm², a second moment of area Iᵧ of 10160 cm⁴, a plastic modulus Wₚₗ,ᵧ of 975 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.

Mass
88 kg/m
Depth
250 mm
Width
250 mm
Wall thickness
12.5 mm
Area
112 cm²
Ask about capacity, buckling or detailing for SHS 250×250×12.5.
🔍 Open the full Steel Catalogue
or pick a unit on any row
SHS Cold-formed section profile showing the dimension symbols used for SHS 250×250×12.5

Dimension symbols for SHS Cold-formed sections. Not to scale.

SHS 250×250×12.5 section properties to EN 10219 · Continental Steel.

Geometry

Depth of sectionh250
Width of sectionb250
Wall thicknesst12.5

Mass and area

Mass per metremass88
Cross-sectional areaA112

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy10160
Elastic section modulus about y-axisWel,y813
Plastic section modulus about y-axisWpl,y975
Radius of gyration about y-axisiy9.52

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz10160
Elastic section modulus about z-axisWel,z813
Plastic section modulus about z-axisWpl,z975
Radius of gyration about z-axisiz9.52

Torsion and warping

Torsion constant (St Venant)It17280
Section modulus for torsionWt1266

Surface area

Surface area per metreSA/m0.936

Is SHS 250×250×12.5 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending30%
103.1 / 346.1 kNm
Shear7%
82.5 / 1147.8 kN
Deflection60%
8.4 / 13.9 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about SHS 250×250×12.5

SHS 250×250×12.5 has a mass of 88 kg/m, tabulated to EN 10219. A 12 m length therefore weighs about 1056 kg, which is the figure to use for a steel take-off or when checking a lift.

SHS 250×250×12.5 has a depth of 250 mm, a width of 250 mm, a wall thickness of 12.5 mm, with a cross-sectional area of 112 cm². These are the nominal dimensions from EN 10219; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 975 cm³, and the elastic modulus Wel,y is 813 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 346 kNm before any stability check.

The second moment of area about the major axis, Iy, is 10,160 cm⁴, and about the minor axis Iz is 10,160 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 9.52 cm about the major axis and iz is 9.52 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 9.52 cm a 1.0 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 17,280 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related SHS Cold-formed sizes

SHS 250×250×8SHS 250×250×9SHS 250×250×10SHS 250×250×12SHS 254×254×6.4SHS 254×254×9.5SHS 254×254×12.7SHS 300×300×6

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All SHS Cold-formed sizes
Square Hollow Sections - Cold-formed
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…