SHS 254×254×12.7 - Section Properties
The SHS 254×254×12.7 is a steel section with a mass of 92.9 kg/m, an overall depth of 254 mm and width of 254 mm and a wall thickness of 12.7 mm. It has a cross-sectional area of 116 cm², a second moment of area Iᵧ of 10830 cm⁴, a plastic modulus Wₚₗ,ᵧ of 1023 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.
Ask about capacity, buckling or detailing for SHS 254×254×12.7.
or pick a unit on any row

Dimension symbols for SHS Cold-formed sections. Not to scale.
Is SHS 254×254×12.7 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 59% utilised, deflection governs
Bending30%
107.8 / 363.2 kNmShear7%
86.3 / 1188.8 kNDeflection59%
8.2 / 13.9 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about SHS 254×254×12.7
Related SHS Cold-formed sizes
Compare with other sections
Side-by-side properties against the closest equivalent in each catalogue.
Learn more
Rate thisNo ratings yet