SHS 250×250×9 - Section Properties
The SHS 250×250×9 is a steel section with a mass of 66.5 kg/m, an overall depth of 250 mm and width of 250 mm and a wall thickness of 9 mm. It has a cross-sectional area of 84 cm², a second moment of area Iᵧ of 7984 cm⁴, a plastic modulus Wₚₗ,ᵧ of 750 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.
Ask about capacity, buckling or detailing for SHS 250×250×9.
or pick a unit on any row

Dimension symbols for SHS Cold-formed sections. Not to scale.
Is SHS 250×250×9 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 59% utilised, deflection governs
Bending30%
79.7 / 266.3 kNmShear7%
63.8 / 860.8 kNDeflection59%
8.3 / 13.9 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about SHS 250×250×9
Related SHS Cold-formed sizes
Compare with other sections
Side-by-side properties against the closest equivalent in each catalogue.
Learn more
Rate thisNo ratings yet
Sign in to join the discussion.
Loading…