SHS 550×550×32 - Section Properties
The SHS 550×550×32 is a steel section with a mass of 500 kg/m, an overall depth of 550 mm and width of 550 mm and a wall thickness of 32 mm. It has a cross-sectional area of 652 cm², a second moment of area Iᵧ of 288700 cm⁴, a plastic modulus Wₚₗ,ᵧ of 12580 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.
Ask about capacity, buckling or detailing for SHS 550×550×32.
or pick a unit on any row

Dimension symbols for SHS sections. Not to scale.
Is SHS 550×550×32 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 60% utilised, deflection governs
Bending30%
1315.9 / 4340.1 kNmShear7%
478.5 / 6493.5 kNDeflection60%
18.2 / 30.6 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about SHS 550×550×32
Related SHS sizes
Learn more
Rate thisNo ratings yet
Sign in to join the discussion.
Loading…