CivilAxisCivilAxis
☕ Support🌐 Community

EHS 150×75×4 - Section Properties

The EHS 150×75×4 is a elliptical hollow section with a mass of 10.7 kg/m, an overall depth of 150 mm and width of 75 mm and a wall thickness of 4 mm. It has a cross-sectional area of 13.6 cm², a second moment of area Iᵧ of 301 cm⁴, a plastic modulus Wₚₗ,ᵧ of 56.1 cm³, tabulated by CivilAxis from BS EN 10210-2:2006 (SCI P363 Blue Book).

Mass
10.7 kg/m
Depth
150 mm
Width
75 mm
Wall thickness
4 mm
Area
13.6 cm²
Ask about capacity, buckling or detailing for EHS 150×75×4.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
EHS Hot-finished section profile showing the dimension symbols used for EHS 150×75×4

Dimension symbols for EHS Hot-finished sections. Not to scale.

EHS 150×75×4 section properties to BS EN 10210-2:2006.

Geometry

Depth of sectionh150
Width of sectionb75
Wall thicknesst4

Mass and area

Mass per metremass10.7
Cross-sectional areaA13.6

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy301
Elastic section modulus about y-axisWel,y40.1
Plastic section modulus about y-axisWpl,y56.1
Radius of gyration about y-axisiy4.7

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz101
Elastic section modulus about z-axisWel,z26.9
Plastic section modulus about z-axisWpl,z34.4
Radius of gyration about z-axisiz2.72

Torsion and warping

Torsion constant (St Venant)It303
Section modulus for torsionWt60.1

Surface area

Surface area per metreSA/m0.363
Surface area per tonneSA/t33.9m²/t

Is EHS 150×75×4 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending25%
5.1 / 19.9 kNm
Shear4%
6.8 / 185.8 kN
Deflection60%
5.0 / 8.3 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about EHS 150×75×4

EHS 150×75×4 has a mass of 10.7 kg/m, tabulated to BS EN 10210-2:2006. A 12 m length therefore weighs about 128 kg, which is the figure to use for a steel take-off or when checking a lift.

EHS 150×75×4 has a depth of 150 mm, a width of 75 mm, a wall thickness of 4 mm, with a cross-sectional area of 13.6 cm². These are the nominal dimensions from BS EN 10210-2:2006; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 56.1 cm³, and the elastic modulus Wel,y is 40.1 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 20 kNm before any stability check.

The second moment of area about the major axis, Iy, is 301 cm⁴, and about the minor axis Iz is 101 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 4.7 cm about the major axis and iz is 2.72 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 2.72 cm a 0.3 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 303 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related EHS Hot-finished sizes

EHS 150×75×5EHS 150×75×6.3EHS 200×100×5EHS 200×100×6.3EHS 200×100×8EHS 200×100×10EHS 200×100×12.5EHS 250×125×6.3

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All EHS Hot-finished sizes
Elliptical Hollow Sections - Hot-finished (BS EN 10210)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…