EHS 200×100×5 - Section Properties
The EHS 200×100×5 is a elliptical hollow section with a mass of 17.9 kg/m, an overall depth of 200 mm and width of 100 mm and a wall thickness of 5 mm. It has a cross-sectional area of 22.8 cm², a second moment of area Iᵧ of 897 cm⁴, a plastic modulus Wₚₗ,ᵧ of 125 cm³, tabulated by CivilAxis from BS EN 10210-2:2006 (SCI P363 Blue Book).
Ask about capacity, buckling or detailing for EHS 200×100×5.
or pick a unit on any row

Dimension symbols for EHS Hot-finished sections. Not to scale.
Is EHS 200×100×5 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 64% utilised, deflection governs
Bending27%
12.0 / 44.4 kNmShear4%
12.0 / 311.5 kNDeflection64%
7.1 / 11.1 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about EHS 200×100×5
Related EHS Hot-finished sizes
Learn more
Rate thisNo ratings yet