EHS 500×250×16 - Section Properties
The EHS 500×250×16 is a elliptical hollow section with a mass of 142 kg/m, an overall depth of 500 mm and width of 250 mm and a wall thickness of 16 mm. It has a cross-sectional area of 180 cm², a second moment of area Iᵧ of 43700 cm⁴, a plastic modulus Wₚₗ,ᵧ of 2460 cm³, tabulated by CivilAxis from BS EN 10210-2:2006 (SCI P363 Blue Book).
Ask about capacity, buckling or detailing for EHS 500×250×16.
or pick a unit on any row

Dimension symbols for EHS Hot-finished sections. Not to scale.
Is EHS 500×250×16 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 61% utilised, deflection governs
Bending26%
225.0 / 873.3 kNmShear4%
90.0 / 2459.5 kNDeflection61%
17.0 / 27.8 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about EHS 500×250×16
Related EHS Hot-finished sizes
Learn more
Rate thisNo ratings yet
Sign in to join the discussion.
Loading…