CivilAxisCivilAxis
☕ Support🌐 Community

HE 100 B - Section Properties

The HE 100 B is a European wide-flange beam (HE) with a mass of 20.4 kg/m, an overall depth of 100 mm and width of 100 mm. It has a cross-sectional area of 26 cm², a second moment of area Iᵧ of 450 cm⁴, a plastic modulus Wₚₗ,ᵧ of 104 cm³, tabulated by CivilAxis from EN 10365 · Continental Steel.

Mass
20.4 kg/m
Depth
100 mm
Width
100 mm
Area
26 cm²
Ask about capacity, buckling or detailing for HE 100 B.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
HE section profile showing the dimension symbols used for HE 100 B

Dimension symbols for HE sections. Not to scale.

HE 100 B section properties to EN 10365 · Continental Steel.

Geometry

Depth of sectionh100
Width of sectionb100
Web thicknesstw6
Flange thicknesstf10
Root fillet radiusr12
Depth between filletsd56

Mass and area

Mass per metremass20.4
Cross-sectional areaA26

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy450
Elastic section modulus about y-axisWel,y89.9
Plastic section modulus about y-axisWpl,y104
Radius of gyration about y-axisiy4.16

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz167
Elastic section modulus about z-axisWel,z33
Plastic section modulus about z-axisWpl,z51.4
Radius of gyration about z-axisiz2.53

Torsion and warping

Torsion constant (St Venant)It9.33
Warping constantIw0.00338

Classification and stability

Flange local-buckling ratiocf/tf3.5
Web local-buckling ratiocw/tw9.33
Buckling parameteru4.401
Torsional indexX8.49

Detailing dimensions

End clearanceC5
Notch dimension NN58
Notch dimension nn22

Surface area

Surface area per metreSA/m0.567

Is HE 100 B strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending30%
11.3 / 36.9 kNm
Shear12%
22.5 / 184.5 kN
Deflection60%
3.3 / 5.6 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about HE 100 B

HE 100 B has a mass of 20.4 kg/m, tabulated to EN 10365. A 12 m length therefore weighs about 245 kg, which is the figure to use for a steel take-off or when checking a lift.

HE 100 B has a depth of 100 mm, a width of 100 mm, a web thickness of 6 mm, a flange thickness of 10 mm, with a cross-sectional area of 26 cm². These are the nominal dimensions from EN 10365; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 104 cm³, and the elastic modulus Wel,y is 89.9 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 37 kNm before any stability check.

The second moment of area about the major axis, Iy, is 450 cm⁴, and about the minor axis Iz is 167 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 3.5 for the flange and cw/tw = 9.33 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 4.16 cm about the major axis and iz is 2.53 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 2.53 cm a 0.3 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 9.33 cm⁴, and the warping constant Iw is 0.00338 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related HE sizes

HE 100 AAHE 100 AHE 100 CHE 100 MHE 120 AAHE 120 AHE 120 BHE 120 C

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All HE sizes
Wide-Flange Beams (HEA/HEB/HEM)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…