HE 450 B - Section Properties

The HE 450 B is a European wide-flange beam (HE) with a mass of 171 kg/m, an overall depth of 450 mm and width of 300 mm. It has a cross-sectional area of 218 cm², a second moment of area Iᵧ of 79900 cm⁴, a plastic modulus Wₚₗ,ᵧ of 3980 cm³, tabulated by CivilAxis from EN 10365 · Continental Steel.

Mass
171 kg/m
Depth
450 mm
Width
300 mm
Area
218 cm²
Ask about capacity, buckling or detailing for HE 450 B.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
HE section profile showing the dimension symbols used for HE 450 B

Dimension symbols for HE sections. Not to scale.

HE 450 B section properties to EN 10365 · Continental Steel.

Geometry

Depth of sectionh450
Width of sectionb300
Web thicknesstw14
Flange thicknesstf26
Root fillet radiusr27
Depth between filletsd344

Mass and area

Mass per metremass171
Cross-sectional areaA218

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy79900
Elastic section modulus about y-axisWel,y3550
Plastic section modulus about y-axisWpl,y3980
Radius of gyration about y-axisiy19.1

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz11700
Elastic section modulus about z-axisWel,z781
Plastic section modulus about z-axisWpl,z1200
Radius of gyration about z-axisiz7.33

Torsion and warping

Torsion constant (St Venant)It448
Warping constantIw5.26

Classification and stability

Flange local-buckling ratiocf/tf4.46
Web local-buckling ratiocw/tw24.6
Buckling parameteru8.039
Torsional indexX16.7

Detailing dimensions

End clearanceC9
Notch dimension NN154
Notch dimension nn54

Surface area

Surface area per metreSA/m2.03

Is HE 450 B strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 59% utilised, deflection governs
Bending31%
440.4 / 1412.9 kNm
Shear12%
195.8 / 1633.1 kN
Deflection59%
14.8 / 25.0 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about HE 450 B

HE 450 B has a mass of 171 kg/m, tabulated to EN 10365. A 12 m length therefore weighs about 2052 kg, which is the figure to use for a steel take-off or when checking a lift.

HE 450 B has a depth of 450 mm, a width of 300 mm, a web thickness of 14 mm, a flange thickness of 26 mm, with a cross-sectional area of 218 cm². These are the nominal dimensions from EN 10365; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 3,980 cm³, and the elastic modulus Wel,y is 3,550 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 1413 kNm before any stability check.

The second moment of area about the major axis, Iy, is 79,900 cm⁴, and about the minor axis Iz is 11,700 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 4.46 for the flange and cw/tw = 24.6 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 19.1 cm about the major axis and iz is 7.33 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 7.33 cm a 0.7 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 448 cm⁴, and the warping constant Iw is 5.26 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related HE sizes

HE 400 BHE 400 MHE 450 AAHE 450 AHE 450 MHE 500 AAHE 500 AHE 500 B

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs H-400x200x22x36

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All HE sizes
Wide-Flange Beams (HEA/HEB/HEM)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…