CivilAxisCivilAxis
☕ Support🌐 Community

HE 500 AA - Section Properties

The HE 500 AA is a European wide-flange beam (HE) with a mass of 107 kg/m, an overall depth of 472 mm and width of 300 mm. It has a cross-sectional area of 137 cm², a second moment of area Iᵧ of 54600 cm⁴, a plastic modulus Wₚₗ,ᵧ of 2580 cm³, tabulated by CivilAxis from EN 10365 · Continental Steel.

Mass
107 kg/m
Depth
472 mm
Width
300 mm
Area
137 cm²
Ask about capacity, buckling or detailing for HE 500 AA.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
HE section profile showing the dimension symbols used for HE 500 AA

Dimension symbols for HE sections. Not to scale.

HE 500 AA section properties to EN 10365 · Continental Steel.

Geometry

Depth of sectionh472
Width of sectionb300
Web thicknesstw10.5
Flange thicknesstf14
Root fillet radiusr27
Depth between filletsd390

Mass and area

Mass per metremass107
Cross-sectional areaA137

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy54600
Elastic section modulus about y-axisWel,y2320
Plastic section modulus about y-axisWpl,y2580
Radius of gyration about y-axisiy20

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz6310
Elastic section modulus about z-axisWel,z421
Plastic section modulus about z-axisWpl,z649
Radius of gyration about z-axisiz6.79

Torsion and warping

Torsion constant (St Venant)It103
Warping constantIw3.3

Classification and stability

Flange local-buckling ratiocf/tf8.41
Web local-buckling ratiocw/tw37.1
Buckling parameteru7.756
Torsional indexX29.9

Detailing dimensions

End clearanceC7
Notch dimension NN156
Notch dimension nn42

Surface area

Surface area per metreSA/m2.08

Is HE 500 AA strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending35%
287.7 / 823.6 kNm
Shear10%
121.1 / 1271.4 kN
Deflection60%
15.7 / 26.4 mm

Class 3 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about HE 500 AA

HE 500 AA has a mass of 107 kg/m, tabulated to EN 10365. A 12 m length therefore weighs about 1284 kg, which is the figure to use for a steel take-off or when checking a lift.

HE 500 AA has a depth of 472 mm, a width of 300 mm, a web thickness of 10.5 mm, a flange thickness of 14 mm, with a cross-sectional area of 137 cm². These are the nominal dimensions from EN 10365; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 2,580 cm³, and the elastic modulus Wel,y is 2,320 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 916 kNm before any stability check.

The second moment of area about the major axis, Iy, is 54,600 cm⁴, and about the minor axis Iz is 6,310 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 8.41 for the flange and cw/tw = 37.1 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 20 cm about the major axis and iz is 6.79 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 6.79 cm a 0.7 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 103 cm⁴, and the warping constant Iw is 3.3 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related HE sizes

HE 450 AAHE 450 AHE 450 BHE 450 MHE 500 AHE 500 BHE 500 MHE 550 AA

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs W 18X76

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All HE sizes
Wide-Flange Beams (HEA/HEB/HEM)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…