HE 550 B - Section Properties

The HE 550 B is a European wide-flange beam (HE) with a mass of 199 kg/m, an overall depth of 550 mm and width of 300 mm. It has a cross-sectional area of 254 cm², a second moment of area Iᵧ of 137000 cm⁴, a plastic modulus Wₚₗ,ᵧ of 5590 cm³, tabulated by CivilAxis from EN 10365 · Continental Steel.

Mass
199 kg/m
Depth
550 mm
Width
300 mm
Area
254 cm²
Ask about capacity, buckling or detailing for HE 550 B.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
HE section profile showing the dimension symbols used for HE 550 B

Dimension symbols for HE sections. Not to scale.

HE 550 B section properties to EN 10365 · Continental Steel.

Geometry

Depth of sectionh550
Width of sectionb300
Web thicknesstw15
Flange thicknesstf29
Root fillet radiusr27
Depth between filletsd438

Mass and area

Mass per metremass199
Cross-sectional areaA254

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy137000
Elastic section modulus about y-axisWel,y4970
Plastic section modulus about y-axisWpl,y5590
Radius of gyration about y-axisiy23.2

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz13100
Elastic section modulus about z-axisWel,z872
Plastic section modulus about z-axisWpl,z1340
Radius of gyration about z-axisiz7.17

Torsion and warping

Torsion constant (St Venant)It610
Warping constantIw8.86

Classification and stability

Flange local-buckling ratiocf/tf3.98
Web local-buckling ratiocw/tw29.2
Buckling parameteru8.045
Torsional indexX19

Detailing dimensions

End clearanceC10
Notch dimension NN154
Notch dimension nn56

Surface area

Surface area per metreSA/m2.22

Is HE 550 B strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending32%
635.3 / 1984.5 kNm
Shear11%
231.0 / 2049.8 kN
Deflection61%
18.6 / 30.6 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about HE 550 B

HE 550 B has a mass of 199 kg/m, tabulated to EN 10365. A 12 m length therefore weighs about 2388 kg, which is the figure to use for a steel take-off or when checking a lift.

HE 550 B has a depth of 550 mm, a width of 300 mm, a web thickness of 15 mm, a flange thickness of 29 mm, with a cross-sectional area of 254 cm². These are the nominal dimensions from EN 10365; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 5,590 cm³, and the elastic modulus Wel,y is 4,970 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 1984 kNm before any stability check.

The second moment of area about the major axis, Iy, is 137,000 cm⁴, and about the minor axis Iz is 13,100 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 3.98 for the flange and cw/tw = 29.2 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 23.2 cm about the major axis and iz is 7.17 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 7.17 cm a 0.7 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 610 cm⁴, and the warping constant Iw is 8.86 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related HE sizes

HE 500 BHE 500 MHE 550 AAHE 550 AHE 550 MHE 600 AAHE 600 AHE 600 B

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs W 21X132

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All HE sizes
Wide-Flange Beams (HEA/HEB/HEM)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…