CivilAxisCivilAxis
☕ Support🌐 Community

HE 600 AA - Section Properties

The HE 600 AA is a European wide-flange beam (HE) with a mass of 129 kg/m, an overall depth of 571 mm and width of 300 mm. It has a cross-sectional area of 164 cm², a second moment of area Iᵧ of 91900 cm⁴, a plastic modulus Wₚₗ,ᵧ of 3620 cm³, tabulated by CivilAxis from EN 10365 · Continental Steel.

Mass
129 kg/m
Depth
571 mm
Width
300 mm
Area
164 cm²
Ask about capacity, buckling or detailing for HE 600 AA.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
HE section profile showing the dimension symbols used for HE 600 AA

Dimension symbols for HE sections. Not to scale.

HE 600 AA section properties to EN 10365 · Continental Steel.

Geometry

Depth of sectionh571
Width of sectionb300
Web thicknesstw12
Flange thicknesstf15.5
Root fillet radiusr27
Depth between filletsd486

Mass and area

Mass per metremass129
Cross-sectional areaA164

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy91900
Elastic section modulus about y-axisWel,y3220
Plastic section modulus about y-axisWpl,y3620
Radius of gyration about y-axisiy23.7

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz6990
Elastic section modulus about z-axisWel,z466
Plastic section modulus about z-axisWpl,z724
Radius of gyration about z-axisiz6.53

Torsion and warping

Torsion constant (St Venant)It142
Warping constantIw5.38

Classification and stability

Flange local-buckling ratiocf/tf7.55
Web local-buckling ratiocw/tw40.5
Buckling parameteru7.651
Torsional indexX33.8

Detailing dimensions

End clearanceC8
Notch dimension NN154
Notch dimension nn44

Surface area

Surface area per metreSA/m2.27

Is HE 600 AA strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 59% utilised, deflection governs
Bending31%
396.8 / 1285.1 kNm
Shear8%
138.0 / 1664.9 kN
Deflection59%
18.9 / 31.9 mm

Class 2 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about HE 600 AA

HE 600 AA has a mass of 129 kg/m, tabulated to EN 10365. A 12 m length therefore weighs about 1548 kg, which is the figure to use for a steel take-off or when checking a lift.

HE 600 AA has a depth of 571 mm, a width of 300 mm, a web thickness of 12 mm, a flange thickness of 15.5 mm, with a cross-sectional area of 164 cm². These are the nominal dimensions from EN 10365; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 3,620 cm³, and the elastic modulus Wel,y is 3,220 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 1285 kNm before any stability check.

The second moment of area about the major axis, Iy, is 91,900 cm⁴, and about the minor axis Iz is 6,990 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 7.55 for the flange and cw/tw = 40.5 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 23.7 cm about the major axis and iz is 6.53 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 6.53 cm a 0.7 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 142 cm⁴, and the warping constant Iw is 5.38 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related HE sizes

HE 550 AAHE 550 AHE 550 BHE 550 MHE 600 AHE 600 BHE 600 MHE 600 x 337

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs UB 610×229×125vs UB 533×210×138vs W 24X84vs W 21X93

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All HE sizes
Wide-Flange Beams (HEA/HEB/HEM)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…