CivilAxisCivilAxis
☕ Support🌐 Community

H-300x150x4.5x6 - Section Properties

The H-300x150x4.5x6 is a European narrow I-beam with a mass of 25 kg/m, an overall depth of 294 mm and width of 148 mm. It has a cross-sectional area of 32.6 cm², a second moment of area Iᵧ of 4940 cm⁴, a plastic modulus Wₚₗ,ᵧ of 375 cm³, tabulated by CivilAxis from Continental Steel.

Mass
25 kg/m
Depth
294 mm
Width
148 mm
Area
32.6 cm²
Ask about capacity, buckling or detailing for H-300x150x4.5x6.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
MB & MC section profile showing the dimension symbols used for H-300x150x4.5x6

Dimension symbols for MB & MC sections. Not to scale.

H-300x150x4.5x6 section properties to Continental Steel.

Geometry

Depth of sectionh294
Width of sectionb148
Web thicknesstw4.5
Flange thicknesstf6
Root fillet radiusr16
Depth between filletsd250

Mass and area

Mass per metremass25
Cross-sectional areaA32.6

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy4940
Elastic section modulus about y-axisWel,y336
Plastic section modulus about y-axisWpl,y375
Radius of gyration about y-axisiy12.3

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz326
Elastic section modulus about z-axisWel,z44
Plastic section modulus about z-axisWpl,z68.4
Radius of gyration about z-axisiz3.16

Torsion and warping

Torsion constant (St Venant)It5.51
Warping constantIw0.068

Classification and stability

Flange local-buckling ratiocf/tf12.3
Web local-buckling ratiocw/tw55.6
Buckling parameteru0.878
Torsional indexX39.7

Detailing dimensions

End clearanceC4
Notch dimension NN82
Notch dimension nn22

Surface area

Surface area per metreSA/m1.14

Is H-300x150x4.5x6 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 59% utilised, deflection governs
Bending34%
40.5 / 119.3 kNm
Shear8%
27.0 / 349.0 kN
Deflection59%
9.8 / 16.7 mm

Class 3 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about H-300x150x4.5x6

H-300x150x4.5x6 has a mass of 25 kg/m, tabulated to Continental Steel. A 12 m length therefore weighs about 300 kg, which is the figure to use for a steel take-off or when checking a lift.

H-300x150x4.5x6 has a depth of 294 mm, a width of 148 mm, a web thickness of 4.5 mm, a flange thickness of 6 mm, with a cross-sectional area of 32.6 cm². These are the nominal dimensions from Continental Steel; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 375 cm³, and the elastic modulus Wel,y is 336 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 133 kNm before any stability check.

The second moment of area about the major axis, Iy, is 4,940 cm⁴, and about the minor axis Iz is 326 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 12.3 for the flange and cw/tw = 55.6 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 12.3 cm about the major axis and iz is 3.16 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 3.16 cm a 0.3 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 5.51 cm⁴, and the warping constant Iw is 0.068 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related MB & MC sizes

H-250x250x9x14-71.8H-250x250x9x14-72.4H-250x250x14x14H-250x250x12x19H-300x150x5.5x8H-300x150x6.5x9H-300x150x6.5x11H-300x150x7.5x12

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All MB & MC sizes
Narrow I-Beams (MB & MC)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…