CivilAxisCivilAxis
☕ Support🌐 Community

H-300x150x7.5x12 - Section Properties

The H-300x150x7.5x12 is a European narrow I-beam with a mass of 46.2 kg/m, an overall depth of 306 mm and width of 151 mm. It has a cross-sectional area of 58.8 cm², a second moment of area Iᵧ of 9514 cm⁴, a plastic modulus Wₚₗ,ᵧ of 702 cm³, tabulated by CivilAxis from Continental Steel.

Mass
46.2 kg/m
Depth
306 mm
Width
151 mm
Area
58.8 cm²
Ask about capacity, buckling or detailing for H-300x150x7.5x12.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
MB & MC section profile showing the dimension symbols used for H-300x150x7.5x12

Dimension symbols for MB & MC sections. Not to scale.

H-300x150x7.5x12 section properties to Continental Steel.

Geometry

Depth of sectionh306
Width of sectionb151
Web thicknesstw7.5
Flange thicknesstf12
Root fillet radiusr13
Depth between filletsd256

Mass and area

Mass per metremass46.2
Cross-sectional areaA58.8

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy9514
Elastic section modulus about y-axisWel,y622
Plastic section modulus about y-axisWpl,y702
Radius of gyration about y-axisiy12.7

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz691
Elastic section modulus about z-axisWel,z91.5
Plastic section modulus about z-axisWpl,z142
Radius of gyration about z-axisiz3.43

Torsion and warping

Torsion constant (St Venant)It24.9
Warping constantIw0.149

Classification and stability

Flange local-buckling ratiocf/tf6.29
Web local-buckling ratiocw/tw34.1
Buckling parameteru0.884
Torsional indexX25.6

Detailing dimensions

End clearanceC6
Notch dimension NN82
Notch dimension nn25

Surface area

Surface area per metreSA/m1.18

Is H-300x150x7.5x12 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending33%
81.0 / 249.2 kNm
Shear10%
54.0 / 544.8 kN
Deflection61%
10.1 / 16.7 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about H-300x150x7.5x12

H-300x150x7.5x12 has a mass of 46.2 kg/m, tabulated to Continental Steel. A 12 m length therefore weighs about 554 kg, which is the figure to use for a steel take-off or when checking a lift.

H-300x150x7.5x12 has a depth of 306 mm, a width of 151 mm, a web thickness of 7.5 mm, a flange thickness of 12 mm, with a cross-sectional area of 58.8 cm². These are the nominal dimensions from Continental Steel; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 702 cm³, and the elastic modulus Wel,y is 622 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 249 kNm before any stability check.

The second moment of area about the major axis, Iy, is 9,514 cm⁴, and about the minor axis Iz is 691 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 6.29 for the flange and cw/tw = 34.1 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 12.7 cm about the major axis and iz is 3.43 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 3.43 cm a 0.3 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 24.9 cm⁴, and the warping constant Iw is 0.149 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related MB & MC sizes

H-300x150x4.5x6H-300x150x5.5x8H-300x150x6.5x9H-300x150x6.5x11H-300x150x11x18H-300x200x7x10H-300x200x8x12-55.8H-300x200x8x12-56.8

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs UB 305×165×46vs UB 305×127×48vs W 12X30

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All MB & MC sizes
Narrow I-Beams (MB & MC)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…