CivilAxisCivilAxis
☕ Support🌐 Community

H-300x300x15x15 - Section Properties

The H-300x300x15x15 is a European narrow I-beam with a mass of 105 kg/m, an overall depth of 300 mm and width of 305 mm. It has a cross-sectional area of 133 cm², a second moment of area Iᵧ of 21310 cm⁴, a plastic modulus Wₚₗ,ᵧ of 1596 cm³, tabulated by CivilAxis from Continental Steel.

Mass
105 kg/m
Depth
300 mm
Width
305 mm
Area
133 cm²
Ask about capacity, buckling or detailing for H-300x300x15x15.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
MB & MC section profile showing the dimension symbols used for H-300x300x15x15

Dimension symbols for MB & MC sections. Not to scale.

H-300x300x15x15 section properties to Continental Steel.

Geometry

Depth of sectionh300
Width of sectionb305
Web thicknesstw15
Flange thicknesstf15
Root fillet radiusr13
Depth between filletsd244

Mass and area

Mass per metremass105
Cross-sectional areaA133

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy21310
Elastic section modulus about y-axisWel,y1421
Plastic section modulus about y-axisWpl,y1596
Radius of gyration about y-axisiy12.6

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz7103
Elastic section modulus about z-axisWel,z466
Plastic section modulus about z-axisWpl,z714
Radius of gyration about z-axisiz7.3

Torsion and warping

Torsion constant (St Venant)It109
Warping constantIw1.44

Classification and stability

Flange local-buckling ratiocf/tf10.2
Web local-buckling ratiocw/tw16.3
Buckling parameteru0.828
Torsional indexX17.9

Detailing dimensions

End clearanceC10
Notch dimension NN155
Notch dimension nn28

Surface area

Surface area per metreSA/m1.77

Is H-300x300x15x15 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending36%
182.3 / 504.5 kNm
Shear12%
121.5 / 976.6 kN
Deflection61%
10.2 / 16.7 mm

Class 3 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about H-300x300x15x15

H-300x300x15x15 has a mass of 105 kg/m, tabulated to Continental Steel. A 12 m length therefore weighs about 1260 kg, which is the figure to use for a steel take-off or when checking a lift.

H-300x300x15x15 has a depth of 300 mm, a width of 305 mm, a web thickness of 15 mm, a flange thickness of 15 mm, with a cross-sectional area of 133 cm². These are the nominal dimensions from Continental Steel; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 1,596 cm³, and the elastic modulus Wel,y is 1,421 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 567 kNm before any stability check.

The second moment of area about the major axis, Iy, is 21,310 cm⁴, and about the minor axis Iz is 7,103 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 10.2 for the flange and cw/tw = 16.3 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 12.6 cm about the major axis and iz is 7.3 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 7.3 cm a 0.7 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 109 cm⁴, and the warping constant Iw is 1.44 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related MB & MC sizes

H-300x200x10x17H-300x300x9x14H-300x300x10x15-93H-300x300x10x15-94H-300x300x11x17H-300x300x13x20H-300x300x15x20H-300x300x20x21

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs UC 305×305×97vs W 12X65vs HE 320 A

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All MB & MC sizes
Narrow I-Beams (MB & MC)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…