CivilAxisCivilAxis
☕ Support🌐 Community

H-300x300x20x21 - Section Properties

The H-300x300x20x21 is a European narrow I-beam with a mass of 147 kg/m, an overall depth of 312 mm and width of 310 mm. It has a cross-sectional area of 187 cm², a second moment of area Iᵧ of 31370 cm⁴, a plastic modulus Wₚₗ,ᵧ of 2295 cm³, tabulated by CivilAxis from Continental Steel.

Mass
147 kg/m
Depth
312 mm
Width
310 mm
Area
187 cm²
Ask about capacity, buckling or detailing for H-300x300x20x21.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
MB & MC section profile showing the dimension symbols used for H-300x300x20x21

Dimension symbols for MB & MC sections. Not to scale.

H-300x300x20x21 section properties to Continental Steel.

Geometry

Depth of sectionh312
Width of sectionb310
Web thicknesstw20
Flange thicknesstf21
Root fillet radiusr18
Depth between filletsd234

Mass and area

Mass per metremass147
Cross-sectional areaA187

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy31370
Elastic section modulus about y-axisWel,y2011
Plastic section modulus about y-axisWpl,y2295
Radius of gyration about y-axisiy13

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz10450
Elastic section modulus about z-axisWel,z674
Plastic section modulus about z-axisWpl,z1040
Radius of gyration about z-axisiz7.48

Torsion and warping

Torsion constant (St Venant)It298
Warping constantIw2.21

Classification and stability

Flange local-buckling ratiocf/tf7.38
Web local-buckling ratiocw/tw11.7
Buckling parameteru0.83
Torsional indexX13

Detailing dimensions

End clearanceC12
Notch dimension NN155
Notch dimension nn39

Surface area

Surface area per metreSA/m1.79

Is H-300x300x20x21 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending32%
263.3 / 814.7 kNm
Shear12%
175.5 / 1405.2 kN
Deflection60%
10.0 / 16.7 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about H-300x300x20x21

H-300x300x20x21 has a mass of 147 kg/m, tabulated to Continental Steel. A 12 m length therefore weighs about 1764 kg, which is the figure to use for a steel take-off or when checking a lift.

H-300x300x20x21 has a depth of 312 mm, a width of 310 mm, a web thickness of 20 mm, a flange thickness of 21 mm, with a cross-sectional area of 187 cm². These are the nominal dimensions from Continental Steel; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 2,295 cm³, and the elastic modulus Wel,y is 2,011 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 815 kNm before any stability check.

The second moment of area about the major axis, Iy, is 31,370 cm⁴, and about the minor axis Iz is 10,450 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 7.38 for the flange and cw/tw = 11.7 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 13 cm about the major axis and iz is 7.48 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 7.48 cm a 0.7 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 298 cm⁴, and the warping constant Iw is 2.21 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related MB & MC sizes

H-300x300x15x15H-300x300x11x17H-300x300x13x20H-300x300x15x20H-350x175x6x9-41.2H-350x175x6x9-41.4H-350x175x7x11-49.4H-350x175x7x11-49.6

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs UC 305×305×137

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All MB & MC sizes
Narrow I-Beams (MB & MC)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…