CivilAxisCivilAxis
☕ Support🌐 Community

H-350x250x8x12 - Section Properties

The H-350x250x8x12 is a European narrow I-beam with a mass of 69.2 kg/m, an overall depth of 336 mm and width of 249 mm. It has a cross-sectional area of 88.2 cm², a second moment of area Iᵧ of 18510 cm⁴, a plastic modulus Wₚₗ,ᵧ of 1215 cm³, tabulated by CivilAxis from Continental Steel.

Mass
69.2 kg/m
Depth
336 mm
Width
249 mm
Area
88.2 cm²
Ask about capacity, buckling or detailing for H-350x250x8x12.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
MB & MC section profile showing the dimension symbols used for H-350x250x8x12

Dimension symbols for MB & MC sections. Not to scale.

H-350x250x8x12 section properties to Continental Steel.

Geometry

Depth of sectionh336
Width of sectionb249
Web thicknesstw8
Flange thicknesstf12
Root fillet radiusr20
Depth between filletsd272

Mass and area

Mass per metremass69.2
Cross-sectional areaA88.2

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy18510
Elastic section modulus about y-axisWel,y1102
Plastic section modulus about y-axisWpl,y1215
Radius of gyration about y-axisiy14.5

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz3093
Elastic section modulus about z-axisWel,z248
Plastic section modulus about z-axisWpl,z380
Radius of gyration about z-axisiz5.92

Torsion and warping

Torsion constant (St Venant)It44.6
Warping constantIw0.812

Classification and stability

Flange local-buckling ratiocf/tf10.4
Web local-buckling ratiocw/tw34
Buckling parameteru0.881
Torsional indexX25.8

Detailing dimensions

End clearanceC6
Notch dimension NN131
Notch dimension nn32

Surface area

Surface area per metreSA/m1.62

Is H-350x250x8x12 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending36%
142.6 / 391.2 kNm
Shear13%
87.8 / 701.0 kN
Deflection60%
10.8 / 18.1 mm

Class 3 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about H-350x250x8x12

H-350x250x8x12 has a mass of 69.2 kg/m, tabulated to Continental Steel. A 12 m length therefore weighs about 830 kg, which is the figure to use for a steel take-off or when checking a lift.

H-350x250x8x12 has a depth of 336 mm, a width of 249 mm, a web thickness of 8 mm, a flange thickness of 12 mm, with a cross-sectional area of 88.2 cm². These are the nominal dimensions from Continental Steel; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 1,215 cm³, and the elastic modulus Wel,y is 1,102 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 431 kNm before any stability check.

The second moment of area about the major axis, Iy, is 18,510 cm⁴, and about the minor axis Iz is 3,093 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 10.4 for the flange and cw/tw = 34 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 14.5 cm about the major axis and iz is 5.92 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 5.92 cm a 0.6 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 44.6 cm⁴, and the warping constant Iw is 0.812 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related MB & MC sizes

H-350x175x8x13H-350x175x9x15H-350x175x10x16H-350x175x11x18H-350x250x9x14-78.1H-350x250x9x14-79.7H-350x250x10x17H-350x250x12x19

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All MB & MC sizes
Narrow I-Beams (MB & MC)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…