H-350x250x10x17 - Section Properties

The H-350x250x10x17 is a European narrow I-beam with a mass of 94.2 kg/m, an overall depth of 346 mm and width of 251 mm. It has a cross-sectional area of 120 cm², a second moment of area Iᵧ of 26440 cm⁴, a plastic modulus Wₚₗ,ᵧ of 1699 cm³, tabulated by CivilAxis from Continental Steel.

Mass
94.2 kg/m
Depth
346 mm
Width
251 mm
Area
120 cm²
Ask about capacity, buckling or detailing for H-350x250x10x17.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
MB & MC section profile showing the dimension symbols used for H-350x250x10x17

Dimension symbols for MB & MC sections. Not to scale.

H-350x250x10x17 section properties to Continental Steel.

Geometry

Depth of sectionh346
Width of sectionb251
Web thicknesstw10
Flange thicknesstf17
Root fillet radiusr20
Depth between filletsd272

Mass and area

Mass per metremass94.2
Cross-sectional areaA120

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy26440
Elastic section modulus about y-axisWel,y1528
Plastic section modulus about y-axisWpl,y1699
Radius of gyration about y-axisiy14.8

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz4488
Elastic section modulus about z-axisWel,z358
Plastic section modulus about z-axisWpl,z547
Radius of gyration about z-axisiz6.12

Torsion and warping

Torsion constant (St Venant)It109
Warping constantIw1.21

Classification and stability

Flange local-buckling ratiocf/tf7.38
Web local-buckling ratiocw/tw27.2
Buckling parameteru0.886
Torsional indexX19.5

Detailing dimensions

End clearanceC7
Notch dimension NN131
Notch dimension nn37

Surface area

Surface area per metreSA/m1.64

Is H-350x250x10x17 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending32%
192.9 / 603.1 kNm
Shear12%
110.3 / 884.6 kN
Deflection61%
11.8 / 19.4 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about H-350x250x10x17

H-350x250x10x17 has a mass of 94.2 kg/m, tabulated to Continental Steel. A 12 m length therefore weighs about 1130 kg, which is the figure to use for a steel take-off or when checking a lift.

H-350x250x10x17 has a depth of 346 mm, a width of 251 mm, a web thickness of 10 mm, a flange thickness of 17 mm, with a cross-sectional area of 120 cm². These are the nominal dimensions from Continental Steel; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 1,699 cm³, and the elastic modulus Wel,y is 1,528 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 603 kNm before any stability check.

The second moment of area about the major axis, Iy, is 26,440 cm⁴, and about the minor axis Iz is 4,488 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 7.38 for the flange and cw/tw = 27.2 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 14.8 cm about the major axis and iz is 6.12 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 6.12 cm a 0.6 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 109 cm⁴, and the warping constant Iw is 1.21 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related MB & MC sizes

H-350x175x11x18H-350x250x8x12H-350x250x9x14-78.1H-350x250x9x14-79.7H-350x250x12x19H-350x350x10x16-113H-350x350x10x16-115H-350x350x12x19-135

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs W 14X61

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All MB & MC sizes
Narrow I-Beams (MB & MC)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…