The H-400x400x18x28 is a European narrow I-beam with a mass of 232 kg/m, an overall depth of 414 mm and width of 405 mm. It has a cross-sectional area of 295 cm², a second moment of area Iᵧ of 92770 cm⁴, a plastic modulus Wₚₗ,ᵧ of 5026 cm³, tabulated by CivilAxis from Continental Steel.

Mass
232 kg/m
Depth
414 mm
Width
405 mm
Area
295 cm²
Ask about capacity, buckling or detailing for H-400x400x18x28.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
MB & MC section profile showing the dimension symbols used for H-400x400x18x28

Dimension symbols for MB & MC sections. Not to scale.

H-400x400x18x28 section properties to Continental Steel.

Geometry

Depth of sectionh414
Width of sectionb405
Web thicknesstw18
Flange thicknesstf28
Root fillet radiusr22
Depth between filletsd314

Mass and area

Mass per metremass232
Cross-sectional areaA295

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy92770
Elastic section modulus about y-axisWel,y4482
Plastic section modulus about y-axisWpl,y5026
Radius of gyration about y-axisiy17.7

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz31030
Elastic section modulus about z-axisWel,z1532
Plastic section modulus about z-axisWpl,z2331
Radius of gyration about z-axisiz10.2

Torsion and warping

Torsion constant (St Venant)It714
Warping constantIw11.6

Classification and stability

Flange local-buckling ratiocf/tf7.23
Web local-buckling ratiocw/tw17.4
Buckling parameteru0.848
Torsional indexX14.1

Detailing dimensions

End clearanceC11
Notch dimension NN204
Notch dimension nn50

Surface area

Surface area per metreSA/m2.37

Is H-400x400x18x28 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending31%
555.4 / 1784.2 kNm
Shear15%
261.4 / 1753.6 kN
Deflection61%
14.3 / 23.6 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about H-400x400x18x28

H-400x400x18x28 has a mass of 232 kg/m, tabulated to Continental Steel. A 12 m length therefore weighs about 2784 kg, which is the figure to use for a steel take-off or when checking a lift.

H-400x400x18x28 has a depth of 414 mm, a width of 405 mm, a web thickness of 18 mm, a flange thickness of 28 mm, with a cross-sectional area of 295 cm². These are the nominal dimensions from Continental Steel; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 5,026 cm³, and the elastic modulus Wel,y is 4,482 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 1784 kNm before any stability check.

The second moment of area about the major axis, Iy, is 92,770 cm⁴, and about the minor axis Iz is 31,030 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 7.23 for the flange and cw/tw = 17.4 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 17.7 cm about the major axis and iz is 10.2 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 10.2 cm a 1.0 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 714 cm⁴, and the warping constant Iw is 11.6 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related MB & MC sizes

H-400x400x11x18H-400x400x13x21H-400x400x21x21H-400x400x16x24H-400x400x25x25H-400x400x20x35H-400x400x30x50H-400x400x45x70

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All MB & MC sizes
Narrow I-Beams (MB & MC)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…