The H-400x400x20x35 is a European narrow I-beam with a mass of 283 kg/m, an overall depth of 428 mm and width of 407 mm. It has a cross-sectional area of 361 cm², a second moment of area Iᵧ of 119200 cm⁴, a plastic modulus Wₚₗ,ᵧ of 6311 cm³, tabulated by CivilAxis from Continental Steel.

Mass
283 kg/m
Depth
428 mm
Width
407 mm
Area
361 cm²
Ask about capacity, buckling or detailing for H-400x400x20x35.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
MB & MC section profile showing the dimension symbols used for H-400x400x20x35

Dimension symbols for MB & MC sections. Not to scale.

H-400x400x20x35 section properties to Continental Steel.

Geometry

Depth of sectionh428
Width of sectionb407
Web thicknesstw20
Flange thicknesstf35
Root fillet radiusr22
Depth between filletsd314

Mass and area

Mass per metremass283
Cross-sectional areaA361

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy119200
Elastic section modulus about y-axisWel,y5570
Plastic section modulus about y-axisWpl,y6311
Radius of gyration about y-axisiy18.2

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz39360
Elastic section modulus about z-axisWel,z1934
Plastic section modulus about z-axisWpl,z2941
Radius of gyration about z-axisiz10.4

Torsion and warping

Torsion constant (St Venant)It1317
Warping constantIw15.2

Classification and stability

Flange local-buckling ratiocf/tf5.81
Web local-buckling ratiocw/tw15.7
Buckling parameteru0.854
Torsional indexX11.6

Detailing dimensions

End clearanceC12
Notch dimension NN204
Notch dimension nn57

Surface area

Surface area per metreSA/m2.41

Is H-400x400x20x35 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending31%
704.4 / 2240.4 kNm
Shear16%
331.5 / 2018.8 kN
Deflection60%
14.1 / 23.6 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about H-400x400x20x35

H-400x400x20x35 has a mass of 283 kg/m, tabulated to Continental Steel. A 12 m length therefore weighs about 3396 kg, which is the figure to use for a steel take-off or when checking a lift.

H-400x400x20x35 has a depth of 428 mm, a width of 407 mm, a web thickness of 20 mm, a flange thickness of 35 mm, with a cross-sectional area of 361 cm². These are the nominal dimensions from Continental Steel; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 6,311 cm³, and the elastic modulus Wel,y is 5,570 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 2240 kNm before any stability check.

The second moment of area about the major axis, Iy, is 119,200 cm⁴, and about the minor axis Iz is 39,360 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 5.81 for the flange and cw/tw = 15.7 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 18.2 cm about the major axis and iz is 10.4 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 10.4 cm a 1.0 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 1,317 cm⁴, and the warping constant Iw is 15.2 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related MB & MC sizes

H-400x400x21x21H-400x400x16x24H-400x400x18x28H-400x400x25x25H-400x400x30x50H-400x400x45x70H-450x200x8x12-65.1H-450x200x8x12-66.2

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs W 14X211

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All MB & MC sizes
Narrow I-Beams (MB & MC)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…