CF RHS 120×40×5 - Section Properties
The CF RHS 120×40×5 is a rectangular hollow section with a mass of 11.3 kg/m, an overall depth of 120 mm and width of 40 mm and a wall thickness of 5 mm. It has a cross-sectional area of 14.4 cm², a second moment of area Iᵧ of 221 cm⁴, a plastic modulus Wₚₗ,ᵧ of 49.4 cm³, tabulated by CivilAxis from BS EN 10219-2:2006 (SCI P363 Blue Book).
Ask about capacity, buckling or detailing for CF RHS 120×40×5.
or pick a unit on any row

Dimension symbols for RHS Cold-formed sections. Not to scale.
Is CF RHS 120×40×5 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 63% utilised, deflection governs
Bending27%
4.7 / 17.5 kNmShear3%
7.5 / 221.4 kNDeflection63%
4.4 / 6.9 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.