CF RHS 200×100×6 - Section Properties
The CF RHS 200×100×6 is a rectangular hollow section with a mass of 26.4 kg/m, an overall depth of 200 mm and width of 100 mm and a wall thickness of 6 mm. It has a cross-sectional area of 33.6 cm², a second moment of area Iᵧ of 1700 cm⁴, a plastic modulus Wₚₗ,ᵧ of 213 cm³, tabulated by CivilAxis from BS EN 10219-2:2006 (SCI P363 Blue Book).
Ask about capacity, buckling or detailing for CF RHS 200×100×6.
or pick a unit on any row

Dimension symbols for RHS Cold-formed sections. Not to scale.
Is CF RHS 200×100×6 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 59% utilised, deflection governs
Bending28%
21.0 / 75.6 kNmShear5%
21.0 / 459.1 kNDeflection59%
6.5 / 11.1 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about CF RHS 200×100×6
Related RHS Cold-formed sizes
Learn more
Rate thisNo ratings yet