CivilAxisCivilAxis
☕ Support🌐 Community

CF RHS 200×150×5 - Section Properties

The CF RHS 200×150×5 is a rectangular hollow section with a mass of 26.2 kg/m, an overall depth of 200 mm and width of 150 mm and a wall thickness of 5 mm. It has a cross-sectional area of 33.4 cm², a second moment of area Iᵧ of 1940 cm⁴, a plastic modulus Wₚₗ,ᵧ of 230 cm³, tabulated by CivilAxis from BS EN 10219-2:2006 (SCI P363 Blue Book).

Mass
26.2 kg/m
Depth
200 mm
Width
150 mm
Wall thickness
5 mm
Area
33.4 cm²
Ask about capacity, buckling or detailing for CF RHS 200×150×5.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
RHS Cold-formed section profile showing the dimension symbols used for CF RHS 200×150×5

Dimension symbols for RHS Cold-formed sections. Not to scale.

CF RHS 200×150×5 section properties to BS EN 10219-2:2006.

Geometry

Depth of sectionh200
Width of sectionb150
Wall thicknesst5

Mass and area

Mass per metremass26.2
Cross-sectional areaA33.4

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy1940
Elastic section modulus about y-axisWel,y193
Plastic section modulus about y-axisWpl,y230
Radius of gyration about y-axisiy7.62

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz1250
Elastic section modulus about z-axisWel,z166
Plastic section modulus about z-axisWpl,z189
Radius of gyration about z-axisiz6.11

Torsion and warping

Torsion constant (St Venant)It2390
Section modulus for torsionWt267

Classification and stability

Flange local-buckling ratiocf/tf27
Web local-buckling ratiocw/tw37

Surface area

Surface area per metreSA/m0.683
Surface area per tonneSA/t26.1m²/t

Is CF RHS 200×150×5 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 59% utilised, deflection governs
Bending29%
24.0 / 81.7 kNm
Shear6%
24.0 / 391.2 kN
Deflection59%
6.5 / 11.1 mm

Class 2 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about CF RHS 200×150×5

CF RHS 200×150×5 has a mass of 26.2 kg/m, tabulated to BS EN 10219-2:2006. A 12 m length therefore weighs about 314 kg, which is the figure to use for a steel take-off or when checking a lift.

CF RHS 200×150×5 has a depth of 200 mm, a width of 150 mm, a wall thickness of 5 mm, with a cross-sectional area of 33.4 cm². These are the nominal dimensions from BS EN 10219-2:2006; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 230 cm³, and the elastic modulus Wel,y is 193 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 82 kNm before any stability check.

The second moment of area about the major axis, Iy, is 1,940 cm⁴, and about the minor axis Iz is 1,250 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 27 for the flange and cw/tw = 37 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 7.62 cm about the major axis and iz is 6.11 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 6.11 cm a 0.6 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 2,390 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related RHS Cold-formed sizes

CF RHS 200×120×6CF RHS 200×120×8CF RHS 200×120×10CF RHS 200×150×4CF RHS 200×150×6CF RHS 200×150×8CF RHS 200×150×10CF RHS 250×150×5

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs RHS 200×100×6.3

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All RHS Cold-formed sizes
Rectangular Hollow Sections - Cold-formed (BS EN 10219)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…