CF RHS 300×200×12 - Section Properties
The CF RHS 300×200×12 is a rectangular hollow section with a mass of 84.8 kg/m, an overall depth of 300 mm and width of 200 mm and a wall thickness of 12 mm. It has a cross-sectional area of 108 cm², a second moment of area Iᵧ of 12800 cm⁴, a plastic modulus Wₚₗ,ᵧ of 1060 cm³, tabulated by CivilAxis from BS EN 10219-2:2006 (SCI P363 Blue Book).
Ask about capacity, buckling or detailing for CF RHS 300×200×12.
or pick a unit on any row

Dimension symbols for RHS Cold-formed sections. Not to scale.
Is CF RHS 300×200×12 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 60% utilised, deflection governs
Bending29%
108.0 / 376.3 kNmShear5%
72.0 / 1328.1 kNDeflection60%
10.0 / 16.7 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about CF RHS 300×200×12
Related RHS Cold-formed sizes
Learn more
Rate thisNo ratings yet
Sign in to join the discussion.
Loading…