CF RHS 80×50×5 - Section Properties
The CF RHS 80×50×5 is a rectangular hollow section with a mass of 8.91 kg/m, an overall depth of 80 mm and width of 50 mm and a wall thickness of 5 mm. It has a cross-sectional area of 11.4 cm², a second moment of area Iᵧ of 89.2 cm⁴, a plastic modulus Wₚₗ,ᵧ of 28.5 cm³, tabulated by CivilAxis from BS EN 10219-2:2006 (SCI P363 Blue Book).
Ask about capacity, buckling or detailing for CF RHS 80×50×5.
or pick a unit on any row

Dimension symbols for RHS Cold-formed sections. Not to scale.
Is CF RHS 80×50×5 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 59% utilised, deflection governs
Bending29%
3.0 / 10.1 kNmShear5%
7.9 / 143.8 kNDeflection59%
2.5 / 4.2 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about CF RHS 80×50×5
Related RHS Cold-formed sizes
Learn more
Rate thisNo ratings yet
Sign in to join the discussion.