CF RHS 90×50×4 - Section Properties
The CF RHS 90×50×4 is a rectangular hollow section with a mass of 7.97 kg/m, an overall depth of 90 mm and width of 50 mm and a wall thickness of 4 mm. It has a cross-sectional area of 10.1 cm², a second moment of area Iᵧ of 103 cm⁴, a plastic modulus Wₚₗ,ᵧ of 28.8 cm³, tabulated by CivilAxis from BS EN 10219-2:2006 (SCI P363 Blue Book).
Ask about capacity, buckling or detailing for CF RHS 90×50×4.
or pick a unit on any row

Dimension symbols for RHS Cold-formed sections. Not to scale.
Is CF RHS 90×50×4 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 61% utilised, deflection governs
Bending26%
2.6 / 10.2 kNmShear4%
5.3 / 133.1 kNDeflection61%
3.4 / 5.6 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about CF RHS 90×50×4
Related RHS Cold-formed sizes
Compare with other sections
Side-by-side properties against the closest equivalent in each catalogue.
Learn more
Rate thisNo ratings yet
Sign in to join the discussion.
Loading…