CivilAxisCivilAxis
☕ Support🌐 Community

RHS 120×80×7.1 - Section Properties

The RHS 120×80×7.1 is a rectangular hollow section with a mass of 20.3 kg/m, an overall depth of 120 mm and width of 80 mm and a wall thickness of 7.1 mm. It has a cross-sectional area of 25.8 cm², a second moment of area Iᵧ of 482 cm⁴, a plastic modulus Wₚₗ,ᵧ of 100 cm³, tabulated by CivilAxis from BS EN 10210-2:2006 (SCI P363 Blue Book).

Mass
20.3 kg/m
Depth
120 mm
Width
80 mm
Wall thickness
7.1 mm
Area
25.8 cm²
Ask about capacity, buckling or detailing for RHS 120×80×7.1.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
RHS Hot-finished section profile showing the dimension symbols used for RHS 120×80×7.1

Dimension symbols for RHS Hot-finished sections. Not to scale.

RHS 120×80×7.1 section properties to BS EN 10210-2:2006.

Geometry

Depth of sectionh120
Width of sectionb80
Wall thicknesst7.1

Mass and area

Mass per metremass20.3
Cross-sectional areaA25.8

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy482
Elastic section modulus about y-axisWel,y80.3
Plastic section modulus about y-axisWpl,y100
Radius of gyration about y-axisiy4.32

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz251
Elastic section modulus about z-axisWel,z62.8
Plastic section modulus about z-axisWpl,z75.2
Radius of gyration about z-axisiz3.12

Torsion and warping

Torsion constant (St Venant)It535
Section modulus for torsionWt101

Classification and stability

Flange local-buckling ratiocf/tf8.27
Web local-buckling ratiocw/tw13.9

Surface area

Surface area per metreSA/m0.382
Surface area per tonneSA/t18.8m²/t

Is RHS 120×80×7.1 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 62% utilised, deflection governs
Bending28%
10.0 / 35.5 kNm
Shear5%
15.9 / 317.3 kN
Deflection62%
4.3 / 6.9 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about RHS 120×80×7.1

RHS 120×80×7.1 has a mass of 20.3 kg/m, tabulated to BS EN 10210-2:2006. A 12 m length therefore weighs about 244 kg, which is the figure to use for a steel take-off or when checking a lift.

RHS 120×80×7.1 has a depth of 120 mm, a width of 80 mm, a wall thickness of 7.1 mm, with a cross-sectional area of 25.8 cm². These are the nominal dimensions from BS EN 10210-2:2006; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 100 cm³, and the elastic modulus Wel,y is 80.3 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 36 kNm before any stability check.

The second moment of area about the major axis, Iy, is 482 cm⁴, and about the minor axis Iz is 251 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 8.27 for the flange and cw/tw = 13.9 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 4.32 cm about the major axis and iz is 3.12 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 3.12 cm a 0.3 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 535 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related RHS Hot-finished sizes

RHS 120×80×3.6RHS 120×80×4RHS 120×80×5RHS 120×80×6.3RHS 120×80×8RHS 120×80×8.8RHS 120×80×10RHS 120×80×12.5

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs CF RHS 120×80×8vs RHS 120×80×8

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All RHS Hot-finished sizes
Rectangular Hollow Sections - Hot-finished (BS EN 10210)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…