RHS 120×80×8 - Section Properties
The RHS 120×80×8 is a rectangular hollow section with a mass of 22.6 kg/m, an overall depth of 120 mm and width of 80 mm and a wall thickness of 8 mm. It has a cross-sectional area of 28.8 cm², a second moment of area Iᵧ of 525 cm⁴, a plastic modulus Wₚₗ,ᵧ of 111 cm³, tabulated by CivilAxis from BS EN 10210-2:2006 (SCI P363 Blue Book).
Ask about capacity, buckling or detailing for RHS 120×80×8.
or pick a unit on any row

Dimension symbols for RHS Hot-finished sections. Not to scale.
Is RHS 120×80×8 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 60% utilised, deflection governs
Bending27%
10.5 / 39.4 kNmShear5%
16.9 / 354.2 kNDeflection60%
4.2 / 6.9 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.