CivilAxisCivilAxis
☕ Support🌐 Community

RHS 150×100×8.8 - Section Properties

The RHS 150×100×8.8 is a rectangular hollow section with a mass of 31.5 kg/m, an overall depth of 150 mm and width of 100 mm and a wall thickness of 8.8 mm. It has a cross-sectional area of 40.1 cm², a second moment of area Iᵧ of 1170 cm⁴, a plastic modulus Wₚₗ,ᵧ of 195 cm³, tabulated by CivilAxis from BS EN 10210-2:2006 (SCI P363 Blue Book).

Mass
31.5 kg/m
Depth
150 mm
Width
100 mm
Wall thickness
8.8 mm
Area
40.1 cm²
Ask about capacity, buckling or detailing for RHS 150×100×8.8.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
RHS Hot-finished section profile showing the dimension symbols used for RHS 150×100×8.8

Dimension symbols for RHS Hot-finished sections. Not to scale.

RHS 150×100×8.8 section properties to BS EN 10210-2:2006.

Geometry

Depth of sectionh150
Width of sectionb100
Wall thicknesst8.8

Mass and area

Mass per metremass31.5
Cross-sectional areaA40.1

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy1170
Elastic section modulus about y-axisWel,y156
Plastic section modulus about y-axisWpl,y195
Radius of gyration about y-axisiy5.4

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz610
Elastic section modulus about z-axisWel,z122
Plastic section modulus about z-axisWpl,z146
Radius of gyration about z-axisiz3.9

Torsion and warping

Torsion constant (St Venant)It1300
Section modulus for torsionWt196

Classification and stability

Flange local-buckling ratiocf/tf8.36
Web local-buckling ratiocw/tw14

Surface area

Surface area per metreSA/m0.477
Surface area per tonneSA/t15.2m²/t

Is RHS 150×100×8.8 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 62% utilised, deflection governs
Bending29%
20.3 / 69.2 kNm
Shear5%
27.0 / 493.1 kN
Deflection62%
5.2 / 8.3 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about RHS 150×100×8.8

RHS 150×100×8.8 has a mass of 31.5 kg/m, tabulated to BS EN 10210-2:2006. A 12 m length therefore weighs about 378 kg, which is the figure to use for a steel take-off or when checking a lift.

RHS 150×100×8.8 has a depth of 150 mm, a width of 100 mm, a wall thickness of 8.8 mm, with a cross-sectional area of 40.1 cm². These are the nominal dimensions from BS EN 10210-2:2006; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 195 cm³, and the elastic modulus Wel,y is 156 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 69 kNm before any stability check.

The second moment of area about the major axis, Iy, is 1,170 cm⁴, and about the minor axis Iz is 610 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 8.36 for the flange and cw/tw = 14 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 5.4 cm about the major axis and iz is 3.9 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 3.9 cm a 0.4 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 1,300 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related RHS Hot-finished sizes

RHS 150×100×5RHS 150×100×6.3RHS 150×100×7.1RHS 150×100×8RHS 150×100×10RHS 150×100×12.5RHS 160×80×4RHS 160×80×5

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs CF RHS 150×100×10vs RHS 150×100×9.5

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All RHS Hot-finished sizes
Rectangular Hollow Sections - Hot-finished (BS EN 10210)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…