CivilAxisCivilAxis
☕ Support🌐 Community

RHS 160×80×5 - Section Properties

The RHS 160×80×5 is a rectangular hollow section with a mass of 17.8 kg/m, an overall depth of 160 mm and width of 80 mm and a wall thickness of 5 mm. It has a cross-sectional area of 22.7 cm², a second moment of area Iᵧ of 744 cm⁴, a plastic modulus Wₚₗ,ᵧ of 116 cm³, tabulated by CivilAxis from BS EN 10210-2:2006 (SCI P363 Blue Book).

Mass
17.8 kg/m
Depth
160 mm
Width
80 mm
Wall thickness
5 mm
Area
22.7 cm²
Ask about capacity, buckling or detailing for RHS 160×80×5.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
RHS Hot-finished section profile showing the dimension symbols used for RHS 160×80×5

Dimension symbols for RHS Hot-finished sections. Not to scale.

RHS 160×80×5 section properties to BS EN 10210-2:2006.

Geometry

Depth of sectionh160
Width of sectionb80
Wall thicknesst5

Mass and area

Mass per metremass17.8
Cross-sectional areaA22.7

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy744
Elastic section modulus about y-axisWel,y93
Plastic section modulus about y-axisWpl,y116
Radius of gyration about y-axisiy5.72

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz249
Elastic section modulus about z-axisWel,z62.3
Plastic section modulus about z-axisWpl,z71.1
Radius of gyration about z-axisiz3.31

Torsion and warping

Torsion constant (St Venant)It600
Section modulus for torsionWt106

Classification and stability

Flange local-buckling ratiocf/tf13
Web local-buckling ratiocw/tw29

Surface area

Surface area per metreSA/m0.467
Surface area per tonneSA/t26.2m²/t

Is RHS 160×80×5 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending31%
12.7 / 41.2 kNm
Shear5%
16.9 / 310.2 kN
Deflection61%
5.1 / 8.3 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about RHS 160×80×5

RHS 160×80×5 has a mass of 17.8 kg/m, tabulated to BS EN 10210-2:2006. A 12 m length therefore weighs about 214 kg, which is the figure to use for a steel take-off or when checking a lift.

RHS 160×80×5 has a depth of 160 mm, a width of 80 mm, a wall thickness of 5 mm, with a cross-sectional area of 22.7 cm². These are the nominal dimensions from BS EN 10210-2:2006; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 116 cm³, and the elastic modulus Wel,y is 93 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 41 kNm before any stability check.

The second moment of area about the major axis, Iy, is 744 cm⁴, and about the minor axis Iz is 249 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 13 for the flange and cw/tw = 29 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 5.72 cm about the major axis and iz is 3.31 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 3.31 cm a 0.3 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 600 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related RHS Hot-finished sizes

RHS 150×100×8.8RHS 150×100×10RHS 150×100×12.5RHS 160×80×4RHS 160×80×6.3RHS 160×80×7.1RHS 160×80×8RHS 160×80×8.8

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs CF RHS 160×80×5

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All RHS Hot-finished sizes
Rectangular Hollow Sections - Hot-finished (BS EN 10210)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…