CF SHS 100×100×5 - Section Properties
The CF SHS 100×100×5 is a square hollow section with a mass of 14.4 kg/m, an overall depth of 100 mm and width of 100 mm and a wall thickness of 5 mm. It has a cross-sectional area of 18.4 cm², a second moment of area Iᵧ of 271 cm⁴, a plastic modulus Wₚₗ,ᵧ of 64.6 cm³, tabulated by CivilAxis from BS EN 10219-2:2006 (SCI P363 Blue Book).
Ask about capacity, buckling or detailing for CF SHS 100×100×5.
or pick a unit on any row

Dimension symbols for SHS Cold-formed sections. Not to scale.
Is CF SHS 100×100×5 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 59% utilised, deflection governs
Bending29%
6.8 / 22.9 kNmShear7%
13.5 / 188.6 kNDeflection59%
3.3 / 5.6 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about CF SHS 100×100×5
Related SHS Cold-formed sizes
Compare with other sections
Side-by-side properties against the closest equivalent in each catalogue.
Learn more
Rate thisNo ratings yet
Sign in to join the discussion.