CF SHS 150×150×5 - Section Properties
The CF SHS 150×150×5 is a square hollow section with a mass of 22.3 kg/m, an overall depth of 150 mm and width of 150 mm and a wall thickness of 5 mm. It has a cross-sectional area of 28.4 cm², a second moment of area Iᵧ of 982 cm⁴, a plastic modulus Wₚₗ,ᵧ of 153 cm³, tabulated by CivilAxis from BS EN 10219-2:2006 (SCI P363 Blue Book).
Ask about capacity, buckling or detailing for CF SHS 150×150×5.
or pick a unit on any row

Dimension symbols for SHS Cold-formed sections. Not to scale.
Is CF SHS 150×150×5 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 61% utilised, deflection governs
Bending31%
16.9 / 54.3 kNmShear8%
22.5 / 291.0 kNDeflection61%
5.1 / 8.3 mmClass 2 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about CF SHS 150×150×5
Related SHS Cold-formed sizes
Compare with other sections
Side-by-side properties against the closest equivalent in each catalogue.
Learn more
Rate thisNo ratings yet
Sign in to join the discussion.