CivilAxisCivilAxis
☕ Support🌐 Community

CF SHS 200×200×12 - Section Properties

The CF SHS 200×200×12 is a square hollow section with a mass of 66 kg/m, an overall depth of 200 mm and width of 200 mm and a wall thickness of 12 mm. It has a cross-sectional area of 84.1 cm², a second moment of area Iᵧ of 4730 cm⁴, a plastic modulus Wₚₗ,ᵧ of 576 cm³, tabulated by CivilAxis from BS EN 10219-2:2006 (SCI P363 Blue Book).

Mass
66 kg/m
Depth
200 mm
Width
200 mm
Wall thickness
12 mm
Area
84.1 cm²
Ask about capacity, buckling or detailing for CF SHS 200×200×12.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
SHS Cold-formed section profile showing the dimension symbols used for CF SHS 200×200×12

Dimension symbols for SHS Cold-formed sections. Not to scale.

CF SHS 200×200×12 section properties to BS EN 10219-2:2006.

Geometry

Depth of sectionh200
Width of sectionb200
Wall thicknesst12

Mass and area

Mass per metremass66
Cross-sectional areaA84.1

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy4730
Elastic section modulus about y-axisWel,y473
Plastic section modulus about y-axisWpl,y576
Radius of gyration about y-axisiy7.5

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz4730
Elastic section modulus about z-axisWel,z473
Plastic section modulus about z-axisWpl,z576
Radius of gyration about z-axisiz7.5

Torsion and warping

Torsion constant (St Venant)It8230
Section modulus for torsionWt743

Surface area

Surface area per metreSA/m0.738
Surface area per tonneSA/t11.2m²/t

Is CF SHS 200×200×12 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending29%
60.0 / 204.5 kNm
Shear7%
60.0 / 861.9 kN
Deflection60%
6.7 / 11.1 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about CF SHS 200×200×12

CF SHS 200×200×12 has a mass of 66 kg/m, tabulated to BS EN 10219-2:2006. A 12 m length therefore weighs about 792 kg, which is the figure to use for a steel take-off or when checking a lift.

CF SHS 200×200×12 has a depth of 200 mm, a width of 200 mm, a wall thickness of 12 mm, with a cross-sectional area of 84.1 cm². These are the nominal dimensions from BS EN 10219-2:2006; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 576 cm³, and the elastic modulus Wel,y is 473 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 204 kNm before any stability check.

The second moment of area about the major axis, Iy, is 4,730 cm⁴, and about the minor axis Iz is 4,730 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 7.5 cm about the major axis and iz is 7.5 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 7.5 cm a 0.8 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 8,230 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related SHS Cold-formed sizes

CF SHS 200×200×6CF SHS 200×200×6.3CF SHS 200×200×8CF SHS 200×200×10CF SHS 200×200×12.5CF SHS 250×250×6CF SHS 250×250×6.3CF SHS 250×250×8

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All SHS Cold-formed sizes
Square Hollow Sections - Cold-formed (BS EN 10219)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…