CivilAxisCivilAxis
☕ Support🌐 Community

CF SHS 300×300×12 - Section Properties

The CF SHS 300×300×12 is a square hollow section with a mass of 104 kg/m, an overall depth of 300 mm and width of 300 mm and a wall thickness of 12 mm. It has a cross-sectional area of 132 cm², a second moment of area Iᵧ of 17800 cm⁴, a plastic modulus Wₚₗ,ᵧ of 1400 cm³, tabulated by CivilAxis from BS EN 10219-2:2006 (SCI P363 Blue Book).

Mass
104 kg/m
Depth
300 mm
Width
300 mm
Wall thickness
12 mm
Area
132 cm²
Ask about capacity, buckling or detailing for CF SHS 300×300×12.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
SHS Cold-formed section profile showing the dimension symbols used for CF SHS 300×300×12

Dimension symbols for SHS Cold-formed sections. Not to scale.

CF SHS 300×300×12 section properties to BS EN 10219-2:2006.

Geometry

Depth of sectionh300
Width of sectionb300
Wall thicknesst12

Mass and area

Mass per metremass104
Cross-sectional areaA132

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy17800
Elastic section modulus about y-axisWel,y1180
Plastic section modulus about y-axisWpl,y1400
Radius of gyration about y-axisiy11.6

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz17800
Elastic section modulus about z-axisWel,z1180
Plastic section modulus about z-axisWpl,z1400
Radius of gyration about z-axisiz11.6

Torsion and warping

Torsion constant (St Venant)It29500
Section modulus for torsionWt1830

Surface area

Surface area per metreSA/m1.14
Surface area per tonneSA/t11m²/t

Is CF SHS 300×300×12 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending30%
148.5 / 497.0 kNm
Shear7%
99.0 / 1352.7 kN
Deflection60%
9.9 / 16.7 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about CF SHS 300×300×12

CF SHS 300×300×12 has a mass of 104 kg/m, tabulated to BS EN 10219-2:2006. A 12 m length therefore weighs about 1248 kg, which is the figure to use for a steel take-off or when checking a lift.

CF SHS 300×300×12 has a depth of 300 mm, a width of 300 mm, a wall thickness of 12 mm, with a cross-sectional area of 132 cm². These are the nominal dimensions from BS EN 10219-2:2006; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 1,400 cm³, and the elastic modulus Wel,y is 1,180 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 497 kNm before any stability check.

The second moment of area about the major axis, Iy, is 17,800 cm⁴, and about the minor axis Iz is 17,800 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 11.6 cm about the major axis and iz is 11.6 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 11.6 cm a 1.2 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 29,500 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related SHS Cold-formed sizes

CF SHS 300×300×6CF SHS 300×300×6.3CF SHS 300×300×8CF SHS 300×300×10CF SHS 300×300×12.5CF SHS 350×350×6CF SHS 350×350×6.3CF SHS 350×350×8

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section