CivilAxisCivilAxis
☕ Support🌐 Community

CF SHS 350×350×12 - Section Properties

The CF SHS 350×350×12 is a square hollow section with a mass of 123 kg/m, an overall depth of 350 mm and width of 350 mm and a wall thickness of 12 mm. It has a cross-sectional area of 156 cm², a second moment of area Iᵧ of 29100 cm⁴, a plastic modulus Wₚₗ,ᵧ of 1950 cm³, tabulated by CivilAxis from BS EN 10219-2:2006 (SCI P363 Blue Book).

Mass
123 kg/m
Depth
350 mm
Width
350 mm
Wall thickness
12 mm
Area
156 cm²
Ask about capacity, buckling or detailing for CF SHS 350×350×12.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
SHS Cold-formed section profile showing the dimension symbols used for CF SHS 350×350×12

Dimension symbols for SHS Cold-formed sections. Not to scale.

CF SHS 350×350×12 section properties to BS EN 10219-2:2006.

Geometry

Depth of sectionh350
Width of sectionb350
Wall thicknesst12

Mass and area

Mass per metremass123
Cross-sectional areaA156

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy29100
Elastic section modulus about y-axisWel,y1660
Plastic section modulus about y-axisWpl,y1950
Radius of gyration about y-axisiy13.6

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz29100
Elastic section modulus about z-axisWel,z1660
Plastic section modulus about z-axisWpl,z1950
Radius of gyration about z-axisiz13.6

Torsion and warping

Torsion constant (St Venant)It47600
Section modulus for torsionWt2550

Surface area

Surface area per metreSA/m1.34
Surface area per tonneSA/t10.9m²/t

Is CF SHS 350×350×12 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending31%
211.3 / 692.3 kNm
Shear8%
120.8 / 1598.7 kN
Deflection61%
11.8 / 19.4 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about CF SHS 350×350×12

CF SHS 350×350×12 has a mass of 123 kg/m, tabulated to BS EN 10219-2:2006. A 12 m length therefore weighs about 1476 kg, which is the figure to use for a steel take-off or when checking a lift.

CF SHS 350×350×12 has a depth of 350 mm, a width of 350 mm, a wall thickness of 12 mm, with a cross-sectional area of 156 cm². These are the nominal dimensions from BS EN 10219-2:2006; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 1,950 cm³, and the elastic modulus Wel,y is 1,660 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 692 kNm before any stability check.

The second moment of area about the major axis, Iy, is 29,100 cm⁴, and about the minor axis Iz is 29,100 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 13.6 cm about the major axis and iz is 13.6 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 13.6 cm a 1.4 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 47,600 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related SHS Cold-formed sizes

CF SHS 350×350×6CF SHS 350×350×6.3CF SHS 350×350×8CF SHS 350×350×10CF SHS 350×350×12.5CF SHS 400×400×6CF SHS 400×400×6.3CF SHS 400×400×8

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All SHS Cold-formed sizes
Square Hollow Sections - Cold-formed (BS EN 10219)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…