SHS 120×120×10 - Section Properties
The SHS 120×120×10 is a square hollow section with a mass of 33.7 kg/m, an overall depth of 120 mm and width of 120 mm and a wall thickness of 10 mm. It has a cross-sectional area of 42.9 cm², a second moment of area Iᵧ of 852 cm⁴, a plastic modulus Wₚₗ,ᵧ of 175 cm³, tabulated by CivilAxis from BS EN 10210-2:2006 (SCI P363 Blue Book).
Ask about capacity, buckling or detailing for SHS 120×120×10.
or pick a unit on any row

Dimension symbols for SHS Hot-finished sections. Not to scale.
Is SHS 120×120×10 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 61% utilised, deflection governs
Bending28%
17.6 / 62.1 kNmShear6%
28.1 / 439.6 kNDeflection61%
4.3 / 6.9 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about SHS 120×120×10
Related SHS Hot-finished sizes
Learn more
Rate thisNo ratings yet
Sign in to join the discussion.
Loading…