CivilAxisCivilAxis
☕ Support🌐 Community

SHS 120×120×6.3 - Section Properties

The SHS 120×120×6.3 is a square hollow section with a mass of 22.2 kg/m, an overall depth of 120 mm and width of 120 mm and a wall thickness of 6.3 mm. It has a cross-sectional area of 28.2 cm², a second moment of area Iᵧ of 603 cm⁴, a plastic modulus Wₚₗ,ᵧ of 120 cm³, tabulated by CivilAxis from BS EN 10210-2:2006 (SCI P363 Blue Book).

Mass
22.2 kg/m
Depth
120 mm
Width
120 mm
Wall thickness
6.3 mm
Area
28.2 cm²
Ask about capacity, buckling or detailing for SHS 120×120×6.3.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
SHS Hot-finished section profile showing the dimension symbols used for SHS 120×120×6.3

Dimension symbols for SHS Hot-finished sections. Not to scale.

SHS 120×120×6.3 section properties to BS EN 10210-2:2006.

Geometry

Depth of sectionh120
Width of sectionb120
Wall thicknesst6.3

Mass and area

Mass per metremass22.2
Cross-sectional areaA28.2

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy603
Elastic section modulus about y-axisWel,y100
Plastic section modulus about y-axisWpl,y120
Radius of gyration about y-axisiy4.62

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz603
Elastic section modulus about z-axisWel,z100
Plastic section modulus about z-axisWpl,z120
Radius of gyration about z-axisiz4.62

Torsion and warping

Torsion constant (St Venant)It950
Section modulus for torsionWt147

Surface area

Surface area per metreSA/m0.464
Surface area per tonneSA/t20.9m²/t

Is SHS 120×120×6.3 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 58% utilised, deflection governs
Bending28%
11.7 / 42.6 kNm
Shear6%
18.8 / 289.0 kN
Deflection58%
4.0 / 6.9 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about SHS 120×120×6.3

SHS 120×120×6.3 has a mass of 22.2 kg/m, tabulated to BS EN 10210-2:2006. A 12 m length therefore weighs about 266 kg, which is the figure to use for a steel take-off or when checking a lift.

SHS 120×120×6.3 has a depth of 120 mm, a width of 120 mm, a wall thickness of 6.3 mm, with a cross-sectional area of 28.2 cm². These are the nominal dimensions from BS EN 10210-2:2006; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 120 cm³, and the elastic modulus Wel,y is 100 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 43 kNm before any stability check.

The second moment of area about the major axis, Iy, is 603 cm⁴, and about the minor axis Iz is 603 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 4.62 cm about the major axis and iz is 4.62 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 4.62 cm a 0.5 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 950 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related SHS Hot-finished sizes

SHS 100×100×10SHS 100×100×12.5SHS 120×120×4SHS 120×120×5SHS 120×120×7.1SHS 120×120×8SHS 120×120×8.8SHS 120×120×10

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs SHS 125×125×6

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All SHS Hot-finished sizes
Square Hollow Sections - Hot-finished (BS EN 10210)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…