CivilAxisCivilAxis
☕ Support🌐 Community

SHS 160×160×12.5 - Section Properties

The SHS 160×160×12.5 is a square hollow section with a mass of 56.6 kg/m, an overall depth of 160 mm and width of 160 mm and a wall thickness of 12.5 mm. It has a cross-sectional area of 72.1 cm², a second moment of area Iᵧ of 2580 cm⁴, a plastic modulus Wₚₗ,ᵧ of 395 cm³, tabulated by CivilAxis from BS EN 10210-2:2006 (SCI P363 Blue Book).

Mass
56.6 kg/m
Depth
160 mm
Width
160 mm
Wall thickness
12.5 mm
Area
72.1 cm²
Ask about capacity, buckling or detailing for SHS 160×160×12.5.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
SHS Hot-finished section profile showing the dimension symbols used for SHS 160×160×12.5

Dimension symbols for SHS Hot-finished sections. Not to scale.

SHS 160×160×12.5 section properties to BS EN 10210-2:2006.

Geometry

Depth of sectionh160
Width of sectionb160
Wall thicknesst12.5

Mass and area

Mass per metremass56.6
Cross-sectional areaA72.1

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy2580
Elastic section modulus about y-axisWel,y322
Plastic section modulus about y-axisWpl,y395
Radius of gyration about y-axisiy5.98

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz2580
Elastic section modulus about z-axisWel,z322
Plastic section modulus about z-axisWpl,z395
Radius of gyration about z-axisiz5.98

Torsion and warping

Torsion constant (St Venant)It4160
Section modulus for torsionWt467

Surface area

Surface area per metreSA/m0.608
Surface area per tonneSA/t10.8m²/t

Is SHS 160×160×12.5 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending31%
43.9 / 140.2 kNm
Shear8%
58.5 / 738.9 kN
Deflection61%
5.1 / 8.3 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about SHS 160×160×12.5

SHS 160×160×12.5 has a mass of 56.6 kg/m, tabulated to BS EN 10210-2:2006. A 12 m length therefore weighs about 679 kg, which is the figure to use for a steel take-off or when checking a lift.

SHS 160×160×12.5 has a depth of 160 mm, a width of 160 mm, a wall thickness of 12.5 mm, with a cross-sectional area of 72.1 cm². These are the nominal dimensions from BS EN 10210-2:2006; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 395 cm³, and the elastic modulus Wel,y is 322 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 140 kNm before any stability check.

The second moment of area about the major axis, Iy, is 2,580 cm⁴, and about the minor axis Iz is 2,580 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 5.98 cm about the major axis and iz is 5.98 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 5.98 cm a 0.6 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 4,160 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related SHS Hot-finished sizes

SHS 160×160×7.1SHS 160×160×8SHS 160×160×8.8SHS 160×160×10SHS 160×160×14.2SHS 160×160×16SHS 180×180×5SHS 180×180×6.3

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All SHS Hot-finished sizes
Square Hollow Sections - Hot-finished (BS EN 10210)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.