CivilAxisCivilAxis
☕ Support🌐 Community

SHS 180×180×6.3 - Section Properties

The SHS 180×180×6.3 is a square hollow section with a mass of 34 kg/m, an overall depth of 180 mm and width of 180 mm and a wall thickness of 6.3 mm. It has a cross-sectional area of 43.3 cm², a second moment of area Iᵧ of 2170 cm⁴, a plastic modulus Wₚₗ,ᵧ of 281 cm³, tabulated by CivilAxis from BS EN 10210-2:2006 (SCI P363 Blue Book).

Mass
34 kg/m
Depth
180 mm
Width
180 mm
Wall thickness
6.3 mm
Area
43.3 cm²
Ask about capacity, buckling or detailing for SHS 180×180×6.3.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
SHS Hot-finished section profile showing the dimension symbols used for SHS 180×180×6.3

Dimension symbols for SHS Hot-finished sections. Not to scale.

SHS 180×180×6.3 section properties to BS EN 10210-2:2006.

Geometry

Depth of sectionh180
Width of sectionb180
Wall thicknesst6.3

Mass and area

Mass per metremass34
Cross-sectional areaA43.3

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy2170
Elastic section modulus about y-axisWel,y241
Plastic section modulus about y-axisWpl,y281
Radius of gyration about y-axisiy7.07

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz2170
Elastic section modulus about z-axisWel,z241
Plastic section modulus about z-axisWpl,z281
Radius of gyration about z-axisiz7.07

Torsion and warping

Torsion constant (St Venant)It3360
Section modulus for torsionWt355

Surface area

Surface area per metreSA/m0.704
Surface area per tonneSA/t20.7m²/t

Is SHS 180×180×6.3 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 62% utilised, deflection governs
Bending32%
32.2 / 99.8 kNm
Shear8%
36.8 / 443.7 kN
Deflection62%
6.0 / 9.7 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about SHS 180×180×6.3

SHS 180×180×6.3 has a mass of 34 kg/m, tabulated to BS EN 10210-2:2006. A 12 m length therefore weighs about 408 kg, which is the figure to use for a steel take-off or when checking a lift.

SHS 180×180×6.3 has a depth of 180 mm, a width of 180 mm, a wall thickness of 6.3 mm, with a cross-sectional area of 43.3 cm². These are the nominal dimensions from BS EN 10210-2:2006; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 281 cm³, and the elastic modulus Wel,y is 241 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 100 kNm before any stability check.

The second moment of area about the major axis, Iy, is 2,170 cm⁴, and about the minor axis Iz is 2,170 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 7.07 cm about the major axis and iz is 7.07 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 7.07 cm a 0.7 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 3,360 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related SHS Hot-finished sizes

SHS 160×160×12.5SHS 160×160×14.2SHS 160×160×16SHS 180×180×5SHS 180×180×7.1SHS 180×180×8SHS 180×180×8.8SHS 180×180×10

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs CF SHS 180×180×6.3

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All SHS Hot-finished sizes
Square Hollow Sections - Hot-finished (BS EN 10210)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…